{"title":"A calculation model of natural gas compression factor","authors":"Weijun Liu","doi":"10.21014/tc9-2022.009","DOIUrl":null,"url":null,"abstract":"“ GBT/17747.2 Natural gas-Calculation of compression factor-Part 2 ” refers to the calculation method of “ AGA8-92DC ” equation, which is very accurate for the calculation of conventional natural gas compressibility factor, but in the calculation process, a large number of intermediate variables, positioning parameters and interactive parameters are introduced, which makes the calculation process more complicated. Based on the critical state of mixed gas, a new fitting formula is proposed to replace the binary interaction parameters used in “ PR ” equation, so as to simplify the calculation process. Compared with the original “ PR ” equation and “ AGA8-92DC ” equation, the calculation results of conventional natural gas compressibility factor and acid natural gas compressibility factor are more close to the laboratory measured compressibility factor.","PeriodicalId":62400,"journal":{"name":"流量控制、测量及可视化(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"流量控制、测量及可视化(英文)","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.21014/tc9-2022.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
“ GBT/17747.2 Natural gas-Calculation of compression factor-Part 2 ” refers to the calculation method of “ AGA8-92DC ” equation, which is very accurate for the calculation of conventional natural gas compressibility factor, but in the calculation process, a large number of intermediate variables, positioning parameters and interactive parameters are introduced, which makes the calculation process more complicated. Based on the critical state of mixed gas, a new fitting formula is proposed to replace the binary interaction parameters used in “ PR ” equation, so as to simplify the calculation process. Compared with the original “ PR ” equation and “ AGA8-92DC ” equation, the calculation results of conventional natural gas compressibility factor and acid natural gas compressibility factor are more close to the laboratory measured compressibility factor.