{"title":"Effects of Neutral Point Grounding Methods on Single-Phase Short Circuit Fault Characteristics","authors":"Amela Kokor, S. Smaka, S. Grebović, V. Helac","doi":"10.1109/INFOTEH53737.2022.9751319","DOIUrl":null,"url":null,"abstract":"Short circuit faults are one of the most common disturbances in power systems that occur because of insulation failure due to a sudden overvoltage condition caused by lightning, switching operations, insulation contamination, etc. Medium voltage power distribution networks use different methods for grounding the neutral point. Influences of these grounding methods on the characteristics of single-phase short circuit fault are discussed in this paper on the example of substation “Bugojno”. Modeling and simulation are implemented in EMTP-RV (Electromagnetic Transient Program-Restructured Version) software. Data recorded by protection system during normal operation and three-phase short circuit fault in the substation are analyzed and used for comparison with simulation results to validate developed model of the observed part of power system. This validated model was then used to analyze the effects of neutral point grounding methods on the characteristics of single-phase short circuit fault.","PeriodicalId":6839,"journal":{"name":"2022 21st International Symposium INFOTEH-JAHORINA (INFOTEH)","volume":"79 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 21st International Symposium INFOTEH-JAHORINA (INFOTEH)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INFOTEH53737.2022.9751319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Short circuit faults are one of the most common disturbances in power systems that occur because of insulation failure due to a sudden overvoltage condition caused by lightning, switching operations, insulation contamination, etc. Medium voltage power distribution networks use different methods for grounding the neutral point. Influences of these grounding methods on the characteristics of single-phase short circuit fault are discussed in this paper on the example of substation “Bugojno”. Modeling and simulation are implemented in EMTP-RV (Electromagnetic Transient Program-Restructured Version) software. Data recorded by protection system during normal operation and three-phase short circuit fault in the substation are analyzed and used for comparison with simulation results to validate developed model of the observed part of power system. This validated model was then used to analyze the effects of neutral point grounding methods on the characteristics of single-phase short circuit fault.
中性点接地方式对单相短路故障特征的影响
短路故障是电力系统中最常见的干扰之一,它是由雷电、开关操作、绝缘污染等引起的突然过电压引起的绝缘失效而引起的。中压配电网中性点接地采用不同的接地方式。本文以“布哥依诺”变电站为例,讨论了各种接地方式对单相短路故障特征的影响。在EMTP-RV(电磁瞬变程序重构版)软件中进行建模和仿真。对变电站正常运行和三相短路故障时保护系统记录的数据进行分析,并与仿真结果进行对比,验证所建立的电力系统观测部分模型的正确性。利用该模型分析了中性点接地方式对单相短路故障特性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信