Using virtual clinical trials to assess objective image quality metrics in the task of microcalcification localization in digital mammography

L. E. Soares, L. Borges, B. Barufaldi, Andrew D. A. Maidment, M. Vieira
{"title":"Using virtual clinical trials to assess objective image quality metrics in the task of microcalcification localization in digital mammography","authors":"L. E. Soares, L. Borges, B. Barufaldi, Andrew D. A. Maidment, M. Vieira","doi":"10.1117/12.2625745","DOIUrl":null,"url":null,"abstract":"Many works have investigated methods to assess the quality of mammography images using objective image quality metrics. However, few studies have evaluated the ability of these metrics to predict the performance of human observers on specific tasks related to mammographic examination that are highly dependent on image quality. The propose of this work is to evaluate the quality of digital mammography acquired at a range of radiation doses through a set of objective metrics and to compare the results with the performance of human observers in the task of locating microcalcification clusters in these images. A dataset of 100 synthetic mammograms was simulated using a virtual clinical trials software. Microcalcification clusters of different sizes and contrasts were computationally inserted into the images. Acquisitions with five different radiation doses were simulated using a noise injection method proposed in a previous work. Four medical physicists with experience in analysis of mammographic images participated in the microcalcification cluster localization tests. The quality of digital mammography images was assessed considering nine well-known objective metrics. The metrics were calculated on both the raw data (DICOM ‘for processing’ tag) and the processed images (DICOM ‘for presentation’ tag). Finally, the association between readers performance and image quality index was conducted by calculating the percentage variation of all metrics as a function of radiation dose, taking the standard dose as a reference. Although the Structural Similarity Index Measure (SSIM) and Peak Signal-to-Noise Ratio (PSNR) are the most used in the literature, our results showed that Quality Index based on Local Variance (QILV) is the objective metric that best describes the behavior of human visual perception with the variation of radiation dose in digital mammography.","PeriodicalId":92005,"journal":{"name":"Breast imaging : 11th International Workshop, IWDM 2012, Philadelphia, PA, USA, July 8-11, 2012 : proceedings. International Workshop on Breast Imaging (11th : 2012 : Philadelphia, Pa.)","volume":"26 1","pages":"1228603 - 1228603-8"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Breast imaging : 11th International Workshop, IWDM 2012, Philadelphia, PA, USA, July 8-11, 2012 : proceedings. International Workshop on Breast Imaging (11th : 2012 : Philadelphia, Pa.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2625745","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Many works have investigated methods to assess the quality of mammography images using objective image quality metrics. However, few studies have evaluated the ability of these metrics to predict the performance of human observers on specific tasks related to mammographic examination that are highly dependent on image quality. The propose of this work is to evaluate the quality of digital mammography acquired at a range of radiation doses through a set of objective metrics and to compare the results with the performance of human observers in the task of locating microcalcification clusters in these images. A dataset of 100 synthetic mammograms was simulated using a virtual clinical trials software. Microcalcification clusters of different sizes and contrasts were computationally inserted into the images. Acquisitions with five different radiation doses were simulated using a noise injection method proposed in a previous work. Four medical physicists with experience in analysis of mammographic images participated in the microcalcification cluster localization tests. The quality of digital mammography images was assessed considering nine well-known objective metrics. The metrics were calculated on both the raw data (DICOM ‘for processing’ tag) and the processed images (DICOM ‘for presentation’ tag). Finally, the association between readers performance and image quality index was conducted by calculating the percentage variation of all metrics as a function of radiation dose, taking the standard dose as a reference. Although the Structural Similarity Index Measure (SSIM) and Peak Signal-to-Noise Ratio (PSNR) are the most used in the literature, our results showed that Quality Index based on Local Variance (QILV) is the objective metric that best describes the behavior of human visual perception with the variation of radiation dose in digital mammography.
使用虚拟临床试验来评估数字乳房x线摄影中微钙化定位任务中的客观图像质量指标
许多工作已经研究了使用客观图像质量指标评估乳房x线摄影图像质量的方法。然而,很少有研究评估这些指标在高度依赖图像质量的乳房x光检查相关的特定任务中预测人类观察者表现的能力。这项工作的建议是通过一组客观指标来评估在一系列辐射剂量下获得的数字乳房x线照相术的质量,并将结果与人类观察者在这些图像中定位微钙化团块的任务中的表现进行比较。使用虚拟临床试验软件模拟了100张合成乳房x光片的数据集。通过计算将不同大小和对比度的微钙化簇插入图像中。使用先前工作中提出的噪声注入方法模拟了五种不同辐射剂量的采集。四位具有乳房x线摄影图像分析经验的医学物理学家参与了微钙化簇定位测试。数字乳房x线摄影图像的质量是根据九个众所周知的客观指标来评估的。这些指标是根据原始数据(DICOM“用于处理”标签)和处理后的图像(DICOM“用于呈现”标签)计算的。最后,以标准剂量为参考,通过计算各指标随辐射剂量的变化百分比,得出阅读器性能与成像质量指标之间的关系。虽然文献中使用最多的是结构相似指数测量(SSIM)和峰值信噪比(PSNR),但我们的研究结果表明,基于局部方差的质量指数(QILV)是最能描述数字乳房x线摄影中人类视觉感知随辐射剂量变化行为的客观指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信