Comparative Evaluation of Methods for Estimation of Soil Salinity

{"title":"Comparative Evaluation of Methods for Estimation of Soil Salinity","authors":"","doi":"10.21921/jas.v10i01.12251","DOIUrl":null,"url":null,"abstract":"Different methods to estimate electrical conductivity (EC) of saturated soil paste extract (ECe) of 1:2 and 1:5 soil: water suspensions were evaluated. Soil samples were taken from different depths (viz. 0-15, 15-30, 30-45, 45-60, and 60-90 cm) of the wheat field under irrigated saline regimes ranging from 1.5 to 12 dSm-1. The relationship between the electrical conductivity of saturated paste extract (ECe) and soil-water suspension extracts (i.e., EC1:2 and EC1:5) was established beside the development of regression models and conversion factors. Regression models relating ECe with EC1:2, EC1:5 were developed with coefficients of determination (R2) 0.98 and 0.99 respectively. The average conversion factor between ECe~ EC1:2 and ECe~ EC1:5  were 2.7 and 7.7, respectively. Methods standardized in the study can be used to estimate the EC of different saturated soil paste extract ratios, which will be less cumbersome and significantly reduce the estimation time. ","PeriodicalId":14972,"journal":{"name":"Journal of AgriSearch","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AgriSearch","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21921/jas.v10i01.12251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Different methods to estimate electrical conductivity (EC) of saturated soil paste extract (ECe) of 1:2 and 1:5 soil: water suspensions were evaluated. Soil samples were taken from different depths (viz. 0-15, 15-30, 30-45, 45-60, and 60-90 cm) of the wheat field under irrigated saline regimes ranging from 1.5 to 12 dSm-1. The relationship between the electrical conductivity of saturated paste extract (ECe) and soil-water suspension extracts (i.e., EC1:2 and EC1:5) was established beside the development of regression models and conversion factors. Regression models relating ECe with EC1:2, EC1:5 were developed with coefficients of determination (R2) 0.98 and 0.99 respectively. The average conversion factor between ECe~ EC1:2 and ECe~ EC1:5  were 2.7 and 7.7, respectively. Methods standardized in the study can be used to estimate the EC of different saturated soil paste extract ratios, which will be less cumbersome and significantly reduce the estimation time. 
土壤盐分估算方法的比较评价
评价了1:2和1:5土水悬浮液饱和土膏浸出物(ECe)电导率的不同估算方法。土壤样本取自小麦田不同深度(即0-15、15-30、30-45、45-60和60-90厘米),灌溉盐碱度为1.5至12 dSm-1。建立了饱和膏体浸膏(ECe)电导率与土壤-水悬浮液浸膏(EC1:2和EC1:5)电导率的关系,并建立了回归模型和换算因子。建立ECe与EC1:2、EC1:5的回归模型,决定系数(R2)分别为0.98和0.99。ECe~ EC1:2和ECe~ EC1:5的平均转换系数分别为2.7和7.7。研究中标准化的方法可用于估算不同饱和土膏体提取比的EC,简化了计算过程,显著缩短了估算时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信