A. Yamamoto, S. Kodama, A. Matsunaga, H. Nakazawa, K. Hayakawa
{"title":"Fluorescence-detected circular dichroism by modulated beam in the wavelength axial direction.","authors":"A. Yamamoto, S. Kodama, A. Matsunaga, H. Nakazawa, K. Hayakawa","doi":"10.1080/10242430212875","DOIUrl":null,"url":null,"abstract":"A novel device is described that permits fluorescence-detected circular dichroism (FDCD) detection in a conventional fluorescence spectrophotometer. FDCD is a phenomenon in which the emission intensity of a chiral analyte depends on the polarization state of the excitations. Although FDCD is a sensitive chiral detection technique, measurement of FDCD by using a special CD spectrometer has involved many difficulties. The proposed device consists of a polarizing prism and a retardation plate that fit on the excitation light side in the sample compartment of the fluorescence spectrophotometer. In this method, a FDCD wave superimposed on the fluorescence excitation spectrum of a chiral analyte was detected. We have also demonstrated the possibility of the enantiomeric purity determination of chiral analytes in real samples.","PeriodicalId":11752,"journal":{"name":"Enantiomer","volume":"25 1","pages":"225-9"},"PeriodicalIF":0.0000,"publicationDate":"2002-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Enantiomer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10242430212875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
A novel device is described that permits fluorescence-detected circular dichroism (FDCD) detection in a conventional fluorescence spectrophotometer. FDCD is a phenomenon in which the emission intensity of a chiral analyte depends on the polarization state of the excitations. Although FDCD is a sensitive chiral detection technique, measurement of FDCD by using a special CD spectrometer has involved many difficulties. The proposed device consists of a polarizing prism and a retardation plate that fit on the excitation light side in the sample compartment of the fluorescence spectrophotometer. In this method, a FDCD wave superimposed on the fluorescence excitation spectrum of a chiral analyte was detected. We have also demonstrated the possibility of the enantiomeric purity determination of chiral analytes in real samples.