Polycyclic Aromatic Hydrocarbons (PAHs) Load and Geo-Electric Characterization of Soils from Ogale Community, Eleme, Rivers State, Nigeria

Ovuru Cyril, Leizou, K. Elijah, M. Ashraf
{"title":"Polycyclic Aromatic Hydrocarbons (PAHs) Load and Geo-Electric Characterization of Soils from Ogale Community, Eleme, Rivers State, Nigeria","authors":"Ovuru Cyril, Leizou, K. Elijah, M. Ashraf","doi":"10.2478/acmy-2020-00010","DOIUrl":null,"url":null,"abstract":"Abstract The aim of this study was to evaluate the polycyclic aromatic hydrocarbons load in soils of Ogale community, Rivers State, Nigeria and as well delineate the lateral and vertical extensions of the soils and groundwater. Geo-electric characterization of the soils and groundwater, using Electrical Resistivity methods (vertical electrical sounding, VES by Abem Terrameter and Gas chromatograph - Flame Ionization Detector (GC-FID) for finger-print was employed. The interpreted VES results revealed four geo-electric subsurface layers. The first layer which has a resistivity value of 60Ωm and a thickness of 2.0M was interpreted as top soil. Underlying the first layer is the second layer which had a resistivity value of 122Ωm with a thickness of 3m, interpreted as lateritic sand. The third layer had a resistivity value of 750Ωm and a thickness of 9.0m, and is interpreted as coarse sand. The fourth layer which had a resistivity value of 1255Ωm and a thickness of 49m is interpreted as very coarse sand. Borehole one was used as control and it is 1.85km away from the Resistivity sampling points. The results revealed that the presence of C10-C40 hydrocarbon which indicates un-weathered to fresh hydrocarbon in parts of the study area and heavy metals were below detection limits. The vulnerability of the aquifer to hydrocarbon contamination was due to high permeability, unconsolidated coarse grained and poorly sorted sands, of the vadose zone as well as shallowness of the aquifer. It is recommended that boreholes in the study area should be of deeper depths, and well constructed to avoid contaminated water from the polluted zone entering the borehole through the annulus.","PeriodicalId":7114,"journal":{"name":"Acta Chemica Malaysia","volume":"47 1","pages":"58 - 65"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chemica Malaysia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/acmy-2020-00010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract The aim of this study was to evaluate the polycyclic aromatic hydrocarbons load in soils of Ogale community, Rivers State, Nigeria and as well delineate the lateral and vertical extensions of the soils and groundwater. Geo-electric characterization of the soils and groundwater, using Electrical Resistivity methods (vertical electrical sounding, VES by Abem Terrameter and Gas chromatograph - Flame Ionization Detector (GC-FID) for finger-print was employed. The interpreted VES results revealed four geo-electric subsurface layers. The first layer which has a resistivity value of 60Ωm and a thickness of 2.0M was interpreted as top soil. Underlying the first layer is the second layer which had a resistivity value of 122Ωm with a thickness of 3m, interpreted as lateritic sand. The third layer had a resistivity value of 750Ωm and a thickness of 9.0m, and is interpreted as coarse sand. The fourth layer which had a resistivity value of 1255Ωm and a thickness of 49m is interpreted as very coarse sand. Borehole one was used as control and it is 1.85km away from the Resistivity sampling points. The results revealed that the presence of C10-C40 hydrocarbon which indicates un-weathered to fresh hydrocarbon in parts of the study area and heavy metals were below detection limits. The vulnerability of the aquifer to hydrocarbon contamination was due to high permeability, unconsolidated coarse grained and poorly sorted sands, of the vadose zone as well as shallowness of the aquifer. It is recommended that boreholes in the study area should be of deeper depths, and well constructed to avoid contaminated water from the polluted zone entering the borehole through the annulus.
尼日利亚河流州Eleme Ogale社区土壤多环芳烃(PAHs)负荷和地电特性
摘要本研究的目的是评估尼日利亚河流州Ogale社区土壤中多环芳烃的负荷,并描绘土壤和地下水的横向和纵向延伸。采用电阻率法(垂直电测深法、阿贝姆测深法、气相色谱仪-火焰离子化检测器(GC-FID)指纹法)对土壤和地下水进行地电表征。解释后的VES结果显示了4个地电亚表层。第一层电阻率为60Ωm,厚度为2.0M,解释为表层土。第一层下为第二层,其电阻率值为122Ωm,厚度为3m,解释为红土砂。第三层电阻率为750Ωm,厚度为9.0m,解释为粗砂。第四层电阻率为1255Ωm,厚度为49m,为极粗砂层。1号井为对照井,距电阻率采样点1.85km。结果表明,部分研究区存在未风化到新鲜烃的C10-C40烃,重金属低于检测限。含水层易受烃污染的原因是含水层的渗透性高、松散的粗粒砂和分选差,含水层较浅。建议研究区钻孔深度要深,施工要好,避免污染区的污水通过环空进入钻孔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信