6/12-channel synchronous digital phasemeter for ultrastable signal characterization and use

Caligaris Massimo, G. Costanzo, C. Calosso
{"title":"6/12-channel synchronous digital phasemeter for ultrastable signal characterization and use","authors":"Caligaris Massimo, G. Costanzo, C. Calosso","doi":"10.1109/FCS.2015.7138934","DOIUrl":null,"url":null,"abstract":"Nowadays, in primary time and frequency laboratories we can find high spectral purity signals in the 10 MHz - 10 GHz range generated from cryogenic oscillators or ultra-stable lasers together with frequency combs. Their short-term stability surpasses by one to two orders of magnitude the performances of active hydrogen masers (AHM), while in the long-term AHMs still have a better behavior. The new technology can be considered mature for what concern spectral purity, but we cannot say the same about complexity, power consumption and reliability. In this sense, it is important to measure ultra-stable sources with respect to AHMs. First, to test their spectral purity or, at least, to give it an upper bound; second to have a continuous monitoring; finally, to combine them in order to get the best of all in term of phase noise and frequency stability. All of these requirements can be satisfied by the system we are developing. It is a multi-channel synchronous and real-time phasemeter based on Tracking Direct Digital Synthesizer (TDDS) technique. The results related to the first prototype are presented.","PeriodicalId":57667,"journal":{"name":"时间频率公报","volume":"11 1","pages":"681-683"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"时间频率公报","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/FCS.2015.7138934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Nowadays, in primary time and frequency laboratories we can find high spectral purity signals in the 10 MHz - 10 GHz range generated from cryogenic oscillators or ultra-stable lasers together with frequency combs. Their short-term stability surpasses by one to two orders of magnitude the performances of active hydrogen masers (AHM), while in the long-term AHMs still have a better behavior. The new technology can be considered mature for what concern spectral purity, but we cannot say the same about complexity, power consumption and reliability. In this sense, it is important to measure ultra-stable sources with respect to AHMs. First, to test their spectral purity or, at least, to give it an upper bound; second to have a continuous monitoring; finally, to combine them in order to get the best of all in term of phase noise and frequency stability. All of these requirements can be satisfied by the system we are developing. It is a multi-channel synchronous and real-time phasemeter based on Tracking Direct Digital Synthesizer (TDDS) technique. The results related to the first prototype are presented.
6/12通道同步数字相位计,用于超稳定信号的表征和使用
目前,在主要的时间和频率实验室中,我们可以发现低温振荡器或超稳定激光器与频率梳一起产生的10 MHz - 10 GHz范围内的高频谱纯度信号。它们的短期稳定性优于有源氢脉泽(AHM)的一到两个数量级,而长期稳定性仍优于有源氢脉泽。在光谱纯度方面,新技术可以被认为是成熟的,但在复杂性、功耗和可靠性方面,我们不能说同样的话。从这个意义上说,测量相对于ahm的超稳定源是很重要的。首先,测试它们的光谱纯度,或者至少给它一个上限;二是要有持续的监测;最后,对它们进行组合,使其在相位噪声和频率稳定性方面达到最佳。我们所开发的系统可以满足所有这些要求。它是一种基于跟踪直接数字合成器(TDDS)技术的多通道同步实时相位计。给出了与第一个样机相关的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
1135
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信