A thin, flexible receiving coil for wireless power transmission based on magnetic induction to an implantable device: Measuring the power efficiency of receiving coils with varying numbers of mounted magnetic sheets
R. Iwashita, M. Ishiwata, Yoji Takaguchi, T. Koike, Issei Hashimoto, K. Shiba
{"title":"A thin, flexible receiving coil for wireless power transmission based on magnetic induction to an implantable device: Measuring the power efficiency of receiving coils with varying numbers of mounted magnetic sheets","authors":"R. Iwashita, M. Ishiwata, Yoji Takaguchi, T. Koike, Issei Hashimoto, K. Shiba","doi":"10.1109/ISMICT.2015.7107493","DOIUrl":null,"url":null,"abstract":"Implanted medical devices require wireless power transmission. The wireless system proposed here uses a transmitting coil that could be worn around the waist to send power to a thin, flexible receiving coil located deep in a liquid NaCl solution of 0.25% mass concentration, simulating conditions in the human body. To determine optimal transmission efficiency, we examined receiving coils mounted with varying numbers of magnetic sheets. A maximum transmission efficiency of 19.2% was obtained at 1.8 MHz with no magnetic sheet. The maximum transmission efficiencies of receiving coils mounted with one sheet and two sheets were 12.5% at 1.3 MHz and 4.68% at 0.8 MHz, respectively. Our investigation confirmed that our wireless power transmission system is able to supply power to the microcontroller in the liquid solution.","PeriodicalId":6624,"journal":{"name":"2015 9th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"83 1","pages":"40-44"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 9th International Symposium on Medical Information and Communication Technology (ISMICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISMICT.2015.7107493","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Implanted medical devices require wireless power transmission. The wireless system proposed here uses a transmitting coil that could be worn around the waist to send power to a thin, flexible receiving coil located deep in a liquid NaCl solution of 0.25% mass concentration, simulating conditions in the human body. To determine optimal transmission efficiency, we examined receiving coils mounted with varying numbers of magnetic sheets. A maximum transmission efficiency of 19.2% was obtained at 1.8 MHz with no magnetic sheet. The maximum transmission efficiencies of receiving coils mounted with one sheet and two sheets were 12.5% at 1.3 MHz and 4.68% at 0.8 MHz, respectively. Our investigation confirmed that our wireless power transmission system is able to supply power to the microcontroller in the liquid solution.