A REVIEW ON LINE TO LINE FAULT ANALYSIS DETECTION

{"title":"A REVIEW ON LINE TO LINE FAULT ANALYSIS DETECTION","authors":"","doi":"10.29121/ijesrt.v11.i2.2022.1","DOIUrl":null,"url":null,"abstract":"As we know that electricity losses during transmission and distribution are extremely high due to which many problems are faced such as varying voltage levels, change in the load current etc. This has been experienced due to the varying electrical consumption and power theft. Also these give rise to fault in power transmission line network and so it is necessary to implement fault detection system in transmission line network. The fault detection system is implemented for three phase electrical distribution system. A practical prototype system can be implemented for fault detection in power system and also the system is successfully designed using 8-bit Microcontrollers which allows the detection of faults. Continuous monitoring of the three phase parameters such as voltage, current and energy consumed is done using data logging system on the PC screen through hyper terminal. There is a Master Slave communication using RS 485 protocol. Communication between Master and Microcontroller is done via RS 232. Comparison of energy units between Master and Slave is done. If difference between the Master and Slave energy units is found, wireless technology GSM (global system for mobile communication) is used to send SMS to a responsible person. Introduction of the mobile communication technology GSM and Microcontroller-based RTU (remote terminal unit) i.e. Master-Slave communication is provided in the paper. This RTU functions as fault detection when abnormality or emergency happens. Also wireless mobile communication technology i.e. GSM is used simultaneously to send message to a responsible person.","PeriodicalId":10891,"journal":{"name":"Day 2 Thu, February 24, 2022","volume":"66 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 2 Thu, February 24, 2022","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29121/ijesrt.v11.i2.2022.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

As we know that electricity losses during transmission and distribution are extremely high due to which many problems are faced such as varying voltage levels, change in the load current etc. This has been experienced due to the varying electrical consumption and power theft. Also these give rise to fault in power transmission line network and so it is necessary to implement fault detection system in transmission line network. The fault detection system is implemented for three phase electrical distribution system. A practical prototype system can be implemented for fault detection in power system and also the system is successfully designed using 8-bit Microcontrollers which allows the detection of faults. Continuous monitoring of the three phase parameters such as voltage, current and energy consumed is done using data logging system on the PC screen through hyper terminal. There is a Master Slave communication using RS 485 protocol. Communication between Master and Microcontroller is done via RS 232. Comparison of energy units between Master and Slave is done. If difference between the Master and Slave energy units is found, wireless technology GSM (global system for mobile communication) is used to send SMS to a responsible person. Introduction of the mobile communication technology GSM and Microcontroller-based RTU (remote terminal unit) i.e. Master-Slave communication is provided in the paper. This RTU functions as fault detection when abnormality or emergency happens. Also wireless mobile communication technology i.e. GSM is used simultaneously to send message to a responsible person.
在线故障分析检测综述
众所周知,在输配电过程中损耗是非常大的,因此会面临电压电平变化、负载电流变化等诸多问题。这是由于不同的电力消耗和电力盗窃而经历的。这些都是造成输电线网络故障的主要原因,因此有必要在输电线网络中实施故障检测系统。实现了三相配电系统的故障检测系统。该系统可用于电力系统的故障检测,并采用8位单片机实现了故障检测。利用数据记录系统通过超级终端在PC屏幕上对电压、电流、能耗等三相参数进行连续监测。采用rs485协议进行主从通信。主控和单片机之间的通信是通过rs232完成的。对主从机的能量单位进行了比较。如果发现主从能量单元之间存在差异,则使用无线技术GSM(全球移动通信系统)向负责人发送SMS。介绍了移动通信技术GSM和基于单片机的远程终端单元RTU (remote terminal unit)即主从通信。当发生异常或紧急情况时,该RTU可用于故障检测。同时也使用无线移动通信技术,即GSM向负责人发送消息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信