Experimental approach of the diffraction effect with random phase transducers

G. Berger, P. Laugier, S. Abouelkaram, P. Bonnin, M. Fink, F. Rieuneau
{"title":"Experimental approach of the diffraction effect with random phase transducers","authors":"G. Berger, P. Laugier, S. Abouelkaram, P. Bonnin, M. Fink, F. Rieuneau","doi":"10.1109/ULTSYM.1989.67148","DOIUrl":null,"url":null,"abstract":"The continuous evolution of the estimated attenuation with respect to the distance between the probe and the sample was evaluated on a foam phantom. Results show large changes rapidly occurring because of the diffraction effect. Random phase transducers (RPTs) were then introduced for attenuation estimation. RPT can be partially or totally incoherent. New diffraction-calibration curves show that no diffraction occurs with the RPT, all the more as they are totally incoherent. As a consequence, the attenuation is very stable as a function of the probe-sample distance. These observations were confirmed through in vitro measurements on human placentas.<<ETX>>","PeriodicalId":89469,"journal":{"name":"Proceedings. IEEE Ultrasonics Symposium","volume":"28 1","pages":"1043-1046 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. IEEE Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1989.67148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The continuous evolution of the estimated attenuation with respect to the distance between the probe and the sample was evaluated on a foam phantom. Results show large changes rapidly occurring because of the diffraction effect. Random phase transducers (RPTs) were then introduced for attenuation estimation. RPT can be partially or totally incoherent. New diffraction-calibration curves show that no diffraction occurs with the RPT, all the more as they are totally incoherent. As a consequence, the attenuation is very stable as a function of the probe-sample distance. These observations were confirmed through in vitro measurements on human placentas.<>
随机相位传感器衍射效应的实验研究
在泡沫模体上评估了估计衰减随探针与样品之间距离的连续演变。结果表明,由于衍射效应的影响,变化很快。然后引入随机相位传感器(RPTs)进行衰减估计。RPT可能是部分或完全不连贯的。新的衍射校准曲线表明,由于RPT完全不相干,因此不发生衍射。因此,衰减作为探针-样本距离的函数是非常稳定的。这些观察结果通过对人类胎盘的体外测量得到了证实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书