Polymer Microchip for Electrophoresis-Mass Spectrometry Fabricated by Hot Embossing and Low Temperature Direct Bonding

T. Suzuki, F. Kitagawa, H. Shinohara, J. Mizuno, K. Otsuka, S. Shoji
{"title":"Polymer Microchip for Electrophoresis-Mass Spectrometry Fabricated by Hot Embossing and Low Temperature Direct Bonding","authors":"T. Suzuki, F. Kitagawa, H. Shinohara, J. Mizuno, K. Otsuka, S. Shoji","doi":"10.1109/SENSOR.2007.4300458","DOIUrl":null,"url":null,"abstract":"Integrated electrophoresis-mass spectrometry polymer devices were fabricated. The electrospray ionization (ESI) emitter tip structure was formed directly at the microchip electrophoresis (MCE) outlet. Since these devices enable negligible dead volume at the electrospray port, efficient spray of the sample necessary for high resolution mass spectrometry (MS) was realized. Stable spray was also achieved at the low flow rate (-0.1 muL/min) without additional pump. Low cost and high performance COP MCE-MS chip was fabricated by hot embossing and low temperature direct bonding.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"65 1","pages":"1617-1620"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Integrated electrophoresis-mass spectrometry polymer devices were fabricated. The electrospray ionization (ESI) emitter tip structure was formed directly at the microchip electrophoresis (MCE) outlet. Since these devices enable negligible dead volume at the electrospray port, efficient spray of the sample necessary for high resolution mass spectrometry (MS) was realized. Stable spray was also achieved at the low flow rate (-0.1 muL/min) without additional pump. Low cost and high performance COP MCE-MS chip was fabricated by hot embossing and low temperature direct bonding.
热压和低温直接键合制备用于电泳-质谱分析的聚合物微芯片
制备了一体化的电泳-质谱聚合物装置。在微芯片电泳(MCE)出口直接形成电喷雾电离(ESI)发射极顶端结构。由于这些装置在电喷雾口的死体积可以忽略不计,因此实现了高分辨率质谱(MS)所需的样品的有效喷雾。在没有额外泵的情况下,在低流量(-0.1 muL/min)下也实现了稳定的喷雾。采用热压成型和低温直接键合技术制备了低成本、高性能的COP MCE-MS芯片。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信