Measuring orbital Volume Using Open Source Software and its Application in Orbitozygomatic Fractures.

IF 0.8 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Taradevi P V Narayan, Vikas Dhupar
{"title":"Measuring orbital Volume Using Open Source Software and its Application in Orbitozygomatic Fractures.","authors":"Taradevi P V Narayan, Vikas Dhupar","doi":"10.1177/19433875231163982","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>Technical note.</p><p><strong>Objective: </strong>Changes in orbital volume can lead to esthetic and functional complications of the orbit. In this article, the procedure to calculate the orbital volume using the open source software Aliza 3D DICOM is described.</p><p><strong>Methods: </strong>This article describes the steps to use this novel software. To validate the software, the normal orbital volume was calculated bilaterally on CT scans with normal orbital anatomy. The volumes of unilateral orbitozygomatic fracture cases were compared.</p><p><strong>Results: </strong>This open source software has easy access. The normal orbital volume calculated using this software was 24.4 cc ± 0.72. In the unilateral orbitozygomatic fracture cases, an increased orbital volume was calculated.</p><p><strong>Conclusions: </strong>This easy access, inexpensive, and convenient computer aided software can be used to calculate orbital volume facilitating treatment plan for correction of the orbit volume.</p>","PeriodicalId":46447,"journal":{"name":"Craniomaxillofacial Trauma & Reconstruction","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11107815/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Craniomaxillofacial Trauma & Reconstruction","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19433875231163982","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/16 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Study design: Technical note.

Objective: Changes in orbital volume can lead to esthetic and functional complications of the orbit. In this article, the procedure to calculate the orbital volume using the open source software Aliza 3D DICOM is described.

Methods: This article describes the steps to use this novel software. To validate the software, the normal orbital volume was calculated bilaterally on CT scans with normal orbital anatomy. The volumes of unilateral orbitozygomatic fracture cases were compared.

Results: This open source software has easy access. The normal orbital volume calculated using this software was 24.4 cc ± 0.72. In the unilateral orbitozygomatic fracture cases, an increased orbital volume was calculated.

Conclusions: This easy access, inexpensive, and convenient computer aided software can be used to calculate orbital volume facilitating treatment plan for correction of the orbit volume.

使用开源软件测量眼眶体积及其在眼眶颧骨骨折中的应用
研究设计:技术说明:眼眶容积的变化可导致眼眶的美学和功能并发症。本文介绍了使用开源软件 Aliza 3D DICOM 计算眼眶体积的过程:本文介绍了使用这款新型软件的步骤。为了验证该软件的有效性,在具有正常眼眶解剖结构的 CT 扫描上计算了双侧正常眼眶体积。结果:结果:该开源软件易于使用。使用该软件计算出的正常眼眶体积为 24.4 cc ± 0.72。在单侧眶颧骨骨折病例中,计算出的眶体积有所增加:结论:这款操作简便、价格低廉的计算机辅助软件可用于计算眼眶体积,有助于制定矫正眼眶体积的治疗方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Craniomaxillofacial Trauma & Reconstruction
Craniomaxillofacial Trauma & Reconstruction DENTISTRY, ORAL SURGERY & MEDICINE-
自引率
0.00%
发文量
39
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信