Absolute fraction of emitted Ps determined by geant4-supported analysis of gamma spectra

Benjamin Rienacker, T. Gigl, G. Nebbia, F. Pino, C. Hugenschmidt
{"title":"Absolute fraction of emitted Ps determined by geant4-supported analysis of gamma spectra","authors":"Benjamin Rienacker, T. Gigl, G. Nebbia, F. Pino, C. Hugenschmidt","doi":"10.1103/physreva.102.062212","DOIUrl":null,"url":null,"abstract":"The fraction of positronium (Ps) emitted from a surface of a germanium single crystal at high temperature is usually assumed to approach unity at zero positron implantation energy. In the experiment, however, the determination of the absolute Ps fraction is not straight forward since recording a reference spectrum with \\SI{100}{\\percent} Ps formation remains demanding. We use GEANT4-simulated detector responses to $2\\gamma$- and $3\\gamma$ radiation sources mimicking positron and Ps annihilation inside the (coincidence) Doppler-broadening spectrometer at NEPOMUC, FRM II, in order to derive a reliable value for the Ps fraction re-emitted from a Ge(100)-target heated close to its melting point. Analysis of the measured spectra by fitting the simulated spectra shows an absolute value of $74\\,\\SI{+-4}{\\percent}$ maximum Ps formation, contradicting the \\SI{100}{\\percent}-assumption.","PeriodicalId":8441,"journal":{"name":"arXiv: Atomic Physics","volume":"31 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv: Atomic Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1103/physreva.102.062212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The fraction of positronium (Ps) emitted from a surface of a germanium single crystal at high temperature is usually assumed to approach unity at zero positron implantation energy. In the experiment, however, the determination of the absolute Ps fraction is not straight forward since recording a reference spectrum with \SI{100}{\percent} Ps formation remains demanding. We use GEANT4-simulated detector responses to $2\gamma$- and $3\gamma$ radiation sources mimicking positron and Ps annihilation inside the (coincidence) Doppler-broadening spectrometer at NEPOMUC, FRM II, in order to derive a reliable value for the Ps fraction re-emitted from a Ge(100)-target heated close to its melting point. Analysis of the measured spectra by fitting the simulated spectra shows an absolute value of $74\,\SI{+-4}{\percent}$ maximum Ps formation, contradicting the \SI{100}{\percent}-assumption.
用geant4支持的伽马光谱分析确定发射Ps的绝对分数
高温下从锗单晶表面发射的正电子(Ps)分数通常被认为在零正电子注入能量下接近于单位。然而,在实验中,绝对Ps分数的确定并不直接,因为记录具有\SI{100}{\percent} Ps形成的参考光谱仍然是要求很高的。我们使用geant4模拟探测器响应$2\gamma$和$3\gamma$放射源模拟正电子和Ps湮灭在NEPOMUC, FRM II的(巧合)多普勒扩频光谱仪内,为了得到一个可靠的值,从Ge(100)目标加热到其熔点附近重新发射的Ps分数。通过拟合模拟光谱对实测光谱进行分析,结果表明,Ps形成的绝对值为$74\,\SI{+-4}{\percent}$最大值,这与\SI{100}{\percent}-的假设相矛盾。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信