{"title":"Modelling and Simulation Study of Conventional Facts-Controllers","authors":"C. Omeje","doi":"10.18488/journal.2.2020.101.43.58","DOIUrl":null,"url":null,"abstract":"This paper presents a comparative analysis of basic forms of Flexible Alternating Current Transmission Systems (FACTS) Devices. The effect of thyristor firing angle on the transmitted voltage and current by the Thyristor Controlled Reactor (TCR) is presented. The real and the reactive power produced by the Thyristor Controlled Reactor at L = 100mH is also presented. The rate of reactive power absorption and injection on the transmission line by two selected FACTS-Devices such as the Static Var Compensator (SVC) and the Unified Power Flow Controller (UPFC) is mathematically modeled and evaluated with respect to a regulated voltage and current magnitude. Simulation results carried out on the circuit models indicate that Thyristor Controlled Reactor absorbed more reactive power of 1.875KVAR with a reduced overload. The Static Var Compensator injected more reactive power of 28.75KVAR to the transmission line while the Unified Power Flow Controller reduced excess overload through phase angle adjustment with the injection of less reactive power of 675VAR to the transmission line grid. All simulations were actualized in MATLAB 7.14 version.","PeriodicalId":8540,"journal":{"name":"Asian Journal of Scientific Research","volume":"28 1","pages":"43-58"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Scientific Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18488/journal.2.2020.101.43.58","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a comparative analysis of basic forms of Flexible Alternating Current Transmission Systems (FACTS) Devices. The effect of thyristor firing angle on the transmitted voltage and current by the Thyristor Controlled Reactor (TCR) is presented. The real and the reactive power produced by the Thyristor Controlled Reactor at L = 100mH is also presented. The rate of reactive power absorption and injection on the transmission line by two selected FACTS-Devices such as the Static Var Compensator (SVC) and the Unified Power Flow Controller (UPFC) is mathematically modeled and evaluated with respect to a regulated voltage and current magnitude. Simulation results carried out on the circuit models indicate that Thyristor Controlled Reactor absorbed more reactive power of 1.875KVAR with a reduced overload. The Static Var Compensator injected more reactive power of 28.75KVAR to the transmission line while the Unified Power Flow Controller reduced excess overload through phase angle adjustment with the injection of less reactive power of 675VAR to the transmission line grid. All simulations were actualized in MATLAB 7.14 version.
传统事实控制器的建模与仿真研究
本文对柔性交流输电系统(FACTS)器件的基本形式进行了比较分析。研究了晶闸管发射角对晶闸管控制电抗器(TCR)传输电压和电流的影响。并给出了在L = 100mH时晶闸管控制电抗器产生的实功率和无功功率。通过两个选定的facts设备,如静态无功补偿器(SVC)和统一潮流控制器(UPFC),对传输线上的无功吸收和注入率进行数学建模,并根据调节电压和电流大小进行评估。对电路模型的仿真结果表明,晶闸管控制电抗器吸收了1.875KVAR的无功功率,并且减少了过载。静态无功补偿器向输电线路注入更多的无功功率28.75KVAR,统一潮流控制器通过调整相角,向输电线路电网注入较少的无功功率675VAR,从而减少了过载。所有仿真均在MATLAB 7.14版本中实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信