Analysis of Geomagnetic Induced Current Modelling and Calculation in Electrical Power Grid

Aina Syahira Amran, N. F. Ab Aziz, Anis Adiba Zawawi, Z. M. Yasin, N. A. Salim
{"title":"Analysis of Geomagnetic Induced Current Modelling and Calculation in Electrical Power Grid","authors":"Aina Syahira Amran, N. F. Ab Aziz, Anis Adiba Zawawi, Z. M. Yasin, N. A. Salim","doi":"10.1109/PECon48942.2020.9314477","DOIUrl":null,"url":null,"abstract":"Geomagnetic induced current (GIC) caused by geomagnetic disturbance (GMD) can be a serious threat to a stable electrical power grid operation. GIC that is induced in the earth magnetic field flows through the neutrals of grounded-wye transformers may lead to increasing reactive power consumption which can result to voltage collapse. Therefore, it is important to study the evaluation of this event on the electrical power grid. This paper presents the analysis of GIC modelling and calculation in a 4 bus test case system using Power World Simulator. The value of calculated GIC using Power World are validated and compared with theoretical using nodal analysis method. Based on the study conducted, it is found that the geomagnetic storm magnitude and direction in degrees can affect the GIC values.","PeriodicalId":6768,"journal":{"name":"2020 IEEE International Conference on Power and Energy (PECon)","volume":"5 1","pages":"194-197"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on Power and Energy (PECon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECon48942.2020.9314477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Geomagnetic induced current (GIC) caused by geomagnetic disturbance (GMD) can be a serious threat to a stable electrical power grid operation. GIC that is induced in the earth magnetic field flows through the neutrals of grounded-wye transformers may lead to increasing reactive power consumption which can result to voltage collapse. Therefore, it is important to study the evaluation of this event on the electrical power grid. This paper presents the analysis of GIC modelling and calculation in a 4 bus test case system using Power World Simulator. The value of calculated GIC using Power World are validated and compared with theoretical using nodal analysis method. Based on the study conducted, it is found that the geomagnetic storm magnitude and direction in degrees can affect the GIC values.
电网中地磁感应电流的建模与计算分析
地磁扰动引起的地磁感应电流严重威胁着电网的稳定运行。在地磁场流过接地变压器中性点时产生的GIC可能导致无功功率增加,从而导致电压崩溃。因此,研究该事件对电网的影响评估具有重要意义。本文介绍了利用Power World Simulator对一个4总线测试用例系统进行GIC建模和计算的分析。采用节点分析法对Power World计算的GIC值进行了验证,并与理论值进行了比较。研究发现,地磁风暴的震级和方向对GIC值有一定的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信