{"title":"Optimization and Validation of Europium-Sensitized Fluorescence Method for Determination of Tetracycline Antibiotics in Water from Fish Farms","authors":"","doi":"10.35666/2232-7266.2021.59.02","DOIUrl":null,"url":null,"abstract":"Sensitized europium fluorescence was used for simple, fast and efficient determination of tetracycline residues in water from fish farms. Tetracycline antibiotics: oxytetracycline (OTC), tetracycline (TC) and chlortetracycline (CTC) were extracted from water samples using polymeric hydrophilic–lipophilic balanced cartridges. After evaporation and pre-concentration, tetracyclines form a complex with europium and citric acid as coligand at pH 8.5. The complex formed has a wide absorption spectrum at 388 nm and a narrow emission maximum at 619 nm resulting from the 5D0 - 7F2 transition within the europium ion. The complex is stable with intensive fluorescence and linear in the concentration range of 5-2500 µg/L for tetracycline and oxytetracycline and 5-1000 µg/L for chlortetracycline. The detection limit was 0.68 µg/L for OTC, 1.29 µg/L for TC and 0.65 µg/L for CTC, respectively.The proposed method is very sensitive and particularly applicable to samples where low concentrations of tetracycline antibiotics are expected.","PeriodicalId":40710,"journal":{"name":"Glasnik Hemicara i Tehnologa Bosne i Hercegovine","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Glasnik Hemicara i Tehnologa Bosne i Hercegovine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35666/2232-7266.2021.59.02","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Sensitized europium fluorescence was used for simple, fast and efficient determination of tetracycline residues in water from fish farms. Tetracycline antibiotics: oxytetracycline (OTC), tetracycline (TC) and chlortetracycline (CTC) were extracted from water samples using polymeric hydrophilic–lipophilic balanced cartridges. After evaporation and pre-concentration, tetracyclines form a complex with europium and citric acid as coligand at pH 8.5. The complex formed has a wide absorption spectrum at 388 nm and a narrow emission maximum at 619 nm resulting from the 5D0 - 7F2 transition within the europium ion. The complex is stable with intensive fluorescence and linear in the concentration range of 5-2500 µg/L for tetracycline and oxytetracycline and 5-1000 µg/L for chlortetracycline. The detection limit was 0.68 µg/L for OTC, 1.29 µg/L for TC and 0.65 µg/L for CTC, respectively.The proposed method is very sensitive and particularly applicable to samples where low concentrations of tetracycline antibiotics are expected.