Screen Printed-Carbon Electrode Modifikasi Bismut untuk Analisis Kadmium dengan Voltametri Siklik

Novianti Novianti, R. V. Manurung, A. Arifin
{"title":"Screen Printed-Carbon Electrode Modifikasi Bismut untuk Analisis Kadmium dengan Voltametri Siklik","authors":"Novianti Novianti, R. V. Manurung, A. Arifin","doi":"10.22146/IJEIS.54138","DOIUrl":null,"url":null,"abstract":"Cadmium (Cd) is a heavy metal that has high toxicity. Cadmium levels need to be considered in an environment that can accumulate and can poison all biotic components. In this research measurements of cadmium metal using bismuth-modified carbon screen electrode  used cyclic voltammetry method. The parameters considered are the resolution of the comparative electrodes and the voltage produced from variations in cadmium concentration. The test results prove the stability of three sensors each at a voltage of 3.3 - 4.6 mV, 9.3-11.4 mV, and 27.4 - 29.8 mV. While the results of the cyclic voltammetry characterization test vary depending on the concentration of cadmium. Concentrations of 0.5-100 ng / mL produce an oxidation peak at a current of 2.03 x 10-5 - 5.00 x 10-5 A. These results show a directly proportional relationship between the cadmium concentration and the resulting current.","PeriodicalId":31590,"journal":{"name":"IJEIS Indonesian Journal of Electronics and Instrumentation Systems","volume":"14 1","pages":"65-74"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJEIS Indonesian Journal of Electronics and Instrumentation Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22146/IJEIS.54138","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Cadmium (Cd) is a heavy metal that has high toxicity. Cadmium levels need to be considered in an environment that can accumulate and can poison all biotic components. In this research measurements of cadmium metal using bismuth-modified carbon screen electrode  used cyclic voltammetry method. The parameters considered are the resolution of the comparative electrodes and the voltage produced from variations in cadmium concentration. The test results prove the stability of three sensors each at a voltage of 3.3 - 4.6 mV, 9.3-11.4 mV, and 27.4 - 29.8 mV. While the results of the cyclic voltammetry characterization test vary depending on the concentration of cadmium. Concentrations of 0.5-100 ng / mL produce an oxidation peak at a current of 2.03 x 10-5 - 5.00 x 10-5 A. These results show a directly proportional relationship between the cadmium concentration and the resulting current.
镉(Cd)是一种具有高毒性的重金属。镉水平需要考虑在一个环境中,可以积累和毒害所有的生物成分。本文采用循环伏安法对铋修饰碳网电极对镉金属的测定进行了研究。考虑的参数是比较电极的分辨率和镉浓度变化产生的电压。测试结果表明,三种传感器在3.3 ~ 4.6 mV、9.3 ~ 11.4 mV和27.4 ~ 29.8 mV电压下均具有良好的稳定性。而循环伏安法表征试验的结果则随镉浓度的不同而不同。浓度0.5-100 ng / mL产生氧化峰电流为2.03 × 10-5 - 5.00 × 10-5 a。这些结果表明镉浓度与产生的电流成正比关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信