Improvement of illumination artifacts in medical ultrasound images using a biologically based algorithm for compression of wide dynamic range

Q3 Arts and Humanities
H. Spitzer, Y. Zimmer
{"title":"Improvement of illumination artifacts in medical ultrasound images using a biologically based algorithm for compression of wide dynamic range","authors":"H. Spitzer, Y. Zimmer","doi":"10.1109/ICECS.2004.1399711","DOIUrl":null,"url":null,"abstract":"Medical ultrasonic B-scans often suffer from inherent artifacts that originate from the attenuation properties of the sonic beam in the living tissues. Common methods such as time gain compensation (TGC) do not yield satisfactory results. We tested a previous algorithm for compression of wide dynamic range in an attempt to address the above problem. This algorithm is based on a biological model that was also suggested for wide dynamic range and lightness constancy. It is based on retinal mechanisms of adaptation (gain control), both 'local', and 'remote', that enable also video image applications by taking into account the dynamics of human adaptation mechanisms. The results indicate that the algorithm succeeded in automatically exposing the details in very bright (i.e., saturated) and very dark zones in the same image. Such an exposure appears as a promising significant tool for better clinical diagnosis.","PeriodicalId":38467,"journal":{"name":"Giornale di Storia Costituzionale","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2004-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale di Storia Costituzionale","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECS.2004.1399711","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Arts and Humanities","Score":null,"Total":0}
引用次数: 1

Abstract

Medical ultrasonic B-scans often suffer from inherent artifacts that originate from the attenuation properties of the sonic beam in the living tissues. Common methods such as time gain compensation (TGC) do not yield satisfactory results. We tested a previous algorithm for compression of wide dynamic range in an attempt to address the above problem. This algorithm is based on a biological model that was also suggested for wide dynamic range and lightness constancy. It is based on retinal mechanisms of adaptation (gain control), both 'local', and 'remote', that enable also video image applications by taking into account the dynamics of human adaptation mechanisms. The results indicate that the algorithm succeeded in automatically exposing the details in very bright (i.e., saturated) and very dark zones in the same image. Such an exposure appears as a promising significant tool for better clinical diagnosis.
利用基于生物学的宽动态范围压缩算法改进医学超声图像中的照明伪影
医学超声b扫描经常受到固有的伪影的影响,这些伪影源于活组织中声波束的衰减特性。常用的时间增益补偿(TGC)等方法不能产生令人满意的结果。为了解决上述问题,我们测试了之前的一种宽动态范围压缩算法。该算法基于生物模型,该模型也被认为具有宽动态范围和亮度恒定。它基于“本地”和“远程”的视网膜适应机制(增益控制),通过考虑到人类适应机制的动态,也使视频图像应用成为可能。结果表明,该算法成功地自动曝光了同一图像中非常亮(即饱和)和非常暗的区域的细节。这种暴露似乎是一种有希望的重要工具,可以更好地进行临床诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Giornale di Storia Costituzionale
Giornale di Storia Costituzionale Arts and Humanities-History
CiteScore
0.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信