Solid Phase Extraction Utilization for Colorimetric Determination of Zinc in Waters, Food, Milk, and Biological Samples

S. AminAlaa, Moalla Sayed Mn, Khalilov Ag
{"title":"Solid Phase Extraction Utilization for Colorimetric Determination of Zinc in Waters, Food, Milk, and Biological Samples","authors":"S. AminAlaa, Moalla Sayed Mn, Khalilov Ag","doi":"10.35840/ijabm/2406","DOIUrl":null,"url":null,"abstract":"A highly rapid, sensitive, and selective method for the determination of zinc based on the reaction of zinc(II) with 5-amino-2-(phenyldiazenyl)phenol (ACDP) and/or 5-amino-2-(ptolyldiazenyl)phenol (ATDP) and the solid phase extraction of the Zn(II)ACDP and/or ATDP complex with Amberlite XAD-2000 was developed, in the presence of pH = 5.6 and 6.2 using ACDP and ATDP, respectively, and Triton X-114 medium. ACDP and/or ATDP reacts with zinc to form a violet complex with a molar ratio of 2:1 (ACDP and/or ATDP to zinc). This complex was enriched by the solid phase extraction with Amberlite XAD-2000. An enrichment factor of 500 was obtained by elution of the complex from the resin with a minimal amount of isopentyl alcohol (0.2 ml). In isopentyl alcohol medium, the molar absorptivity of the complex is 1.13 × 106 and 1.37 × 106 L/mol cm at 647 and 662 nm using ACDP and ATDP, respectively, against a reagent blank prepared in a similar way without zinc. Beer's law is obeyed in the range of 5.0160 ng/ml in the measured solution. The relative standard deviation for 10 replicate samples of 50 ng/ml level is 1.26 and 1.47%, respectively. The detection and quantification limits reaches 1.5 and 4.7 ng/ml in the original samples. The presented procedure was successfully applied for determination of zinc content in real samples such as waters, food, milk, and biological samples with satisfactory results.","PeriodicalId":13753,"journal":{"name":"International Journal of Analytical and Bioanalytical Methods","volume":"58 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Analytical and Bioanalytical Methods","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35840/ijabm/2406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A highly rapid, sensitive, and selective method for the determination of zinc based on the reaction of zinc(II) with 5-amino-2-(phenyldiazenyl)phenol (ACDP) and/or 5-amino-2-(ptolyldiazenyl)phenol (ATDP) and the solid phase extraction of the Zn(II)ACDP and/or ATDP complex with Amberlite XAD-2000 was developed, in the presence of pH = 5.6 and 6.2 using ACDP and ATDP, respectively, and Triton X-114 medium. ACDP and/or ATDP reacts with zinc to form a violet complex with a molar ratio of 2:1 (ACDP and/or ATDP to zinc). This complex was enriched by the solid phase extraction with Amberlite XAD-2000. An enrichment factor of 500 was obtained by elution of the complex from the resin with a minimal amount of isopentyl alcohol (0.2 ml). In isopentyl alcohol medium, the molar absorptivity of the complex is 1.13 × 106 and 1.37 × 106 L/mol cm at 647 and 662 nm using ACDP and ATDP, respectively, against a reagent blank prepared in a similar way without zinc. Beer's law is obeyed in the range of 5.0160 ng/ml in the measured solution. The relative standard deviation for 10 replicate samples of 50 ng/ml level is 1.26 and 1.47%, respectively. The detection and quantification limits reaches 1.5 and 4.7 ng/ml in the original samples. The presented procedure was successfully applied for determination of zinc content in real samples such as waters, food, milk, and biological samples with satisfactory results.
固相萃取比色法测定水、食品、牛奶和生物样品中的锌
在pH = 5.6和6.2的条件下,分别使用ACDP和ATDP, Triton X-114培养基,通过锌(II)与5-氨基-2-(苯二氮基)苯酚(ACDP)和/或5-氨基-2-(聚二氮基)苯酚(ATDP)反应,并与Amberlite XAD-2000固相萃取Zn(II)ACDP和/或ATDP配合物,建立了一种快速、灵敏、选择性高的锌测定方法。ACDP和/或ATDP与锌反应形成摩尔比为2:1的紫色络合物(ACDP和/或ATDP与锌)。该配合物用Amberlite XAD-2000固相萃取富集。用微量异戊醇(0.2 ml)从树脂中洗脱络合物,富集系数为500。在异戊醇介质中,在647 nm和662 nm处,ACDP和ATDP的摩尔吸光度分别为1.13 × 106和1.37 × 106 L/mol cm。被测溶液在5.0160 ng/ml范围内符合比尔定律。50 ng/ml水平的10个重复样品的相对标准偏差分别为1.26和1.47%。原样品的检出定量限分别为1.5、4.7 ng/ml。该方法成功地应用于水、食品、牛奶和生物样品中锌含量的测定,结果令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书