Intrasession Repeatability of the Contact Angle Measured Using the Captive Bubble Method and Agreement Assessed Between Different Analysis Software Programs.

I. Sánchez, F. J. Carmona, Sara Gonzalez-Puertas, A. Valiente, Raúl Martín
{"title":"Intrasession Repeatability of the Contact Angle Measured Using the Captive Bubble Method and Agreement Assessed Between Different Analysis Software Programs.","authors":"I. Sánchez, F. J. Carmona, Sara Gonzalez-Puertas, A. Valiente, Raúl Martín","doi":"10.1097/ICL.0000000000000655","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\nThe material biocompatibility of hydrogel and silicone hydrogel (SiHy) contact lens (CL) is of paramount importance in CL wear because a decrease in CL wettability reduces wearer comfort and increases wearer dropout. The aim of this study is to report on the repeatability and agreement between two different software programs that measure the contact angle with the captive bubble method in marketed CLs, which will help to translate this information into clinical practice.\n\n\nMETHODS\nThe contact angle of 23 different CLs was measured with the captive bubble method using 2 software programs: FTÅ200 and ImageJ. Three consecutive measurements were conducted for each CL. Reproducibility, repeatability, and agreement values were calculated according to the British Standards Institute and the International Organization for Standardization.\n\n\nRESULTS\nAll methods showed good repeatability values in both CL materials (coefficient of variation <1.51%, Sw <2.26°, intraclass correlation coefficient >0.89, and the range of limits of agreement was between 7.22° and 7.57°). Higher concordance was achieved between the spherical and nonspherical options when using FTÅ200 software than when using ImageJ software. Statistically significant differences (P<0.05) between the 2 software programs were found, and they ranged between 5° and 10°.\n\n\nCONCLUSIONS\nThe captive bubble method showed great repeatability in measuring the contact angle in marketed CLs with both software programs (FTÅ200 and ImageJ) assessed in this study. However, differences in the measured contact angles suggest that these techniques are not interchangeable. Therefore, standardization is recommended for contact angle measurement in hydrogel CL materials to facilitate comparisons, to improve clinical use of this information, and to analyze their impact in CL user comfort.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"19 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens: Science & Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000655","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

OBJECTIVES The material biocompatibility of hydrogel and silicone hydrogel (SiHy) contact lens (CL) is of paramount importance in CL wear because a decrease in CL wettability reduces wearer comfort and increases wearer dropout. The aim of this study is to report on the repeatability and agreement between two different software programs that measure the contact angle with the captive bubble method in marketed CLs, which will help to translate this information into clinical practice. METHODS The contact angle of 23 different CLs was measured with the captive bubble method using 2 software programs: FTÅ200 and ImageJ. Three consecutive measurements were conducted for each CL. Reproducibility, repeatability, and agreement values were calculated according to the British Standards Institute and the International Organization for Standardization. RESULTS All methods showed good repeatability values in both CL materials (coefficient of variation <1.51%, Sw <2.26°, intraclass correlation coefficient >0.89, and the range of limits of agreement was between 7.22° and 7.57°). Higher concordance was achieved between the spherical and nonspherical options when using FTÅ200 software than when using ImageJ software. Statistically significant differences (P<0.05) between the 2 software programs were found, and they ranged between 5° and 10°. CONCLUSIONS The captive bubble method showed great repeatability in measuring the contact angle in marketed CLs with both software programs (FTÅ200 and ImageJ) assessed in this study. However, differences in the measured contact angles suggest that these techniques are not interchangeable. Therefore, standardization is recommended for contact angle measurement in hydrogel CL materials to facilitate comparisons, to improve clinical use of this information, and to analyze their impact in CL user comfort.
用俘获泡法测量接触角的可重复性及不同分析软件程序间的一致性评估。
目的:水凝胶和硅酮水凝胶(SiHy)隐形眼镜(CL)的材料生物相容性对佩戴CL至关重要,因为CL润湿性的降低降低了佩戴者的舒适度,增加了佩戴者的辍学。本研究的目的是报告两种不同的软件程序之间的可重复性和一致性,这将有助于将这些信息转化为临床实践。方法利用FTÅ200和ImageJ软件,采用俘获泡法测量23种不同细胞的接触角。每个CL连续测量三次。再现性、可重复性和一致性值是根据英国标准协会和国际标准化组织计算的。结果两种方法均具有良好的重复性(变异系数为0.89,一致性范围为7.22°~ 7.57°)。当使用FTÅ200软件时,球面和非球面选项之间的一致性比使用ImageJ软件时更高。两种软件之间的差异有统计学意义(P<0.05),差异范围为5°~ 10°。结论俘获泡法对市售CLs的接触角测量具有良好的重复性,同时采用FTÅ200和ImageJ两种软件进行评估。然而,测量接触角的差异表明这些技术是不可互换的。因此,建议对水凝胶CL材料的接触角测量进行标准化,以方便比较,提高该信息的临床使用,并分析其对CL使用者舒适度的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信