Kajian Kebutuhan Ventilasi Alami Ruangan pada Bangunan Gedung

Kennardy Winardo, Mia Wimala
{"title":"Kajian Kebutuhan Ventilasi Alami Ruangan pada Bangunan Gedung","authors":"Kennardy Winardo, Mia Wimala","doi":"10.21776/ub.rekayasasipil.2023.017.02.2","DOIUrl":null,"url":null,"abstract":"The Indonesian National Standard (SNI) 6572:2001 on natural ventilation in buildings has not been updated in the last 20 years, while similar standards in other countries have been periodically improved. The development of science and technology, environmental conditions, coupled with the COVID-19 pandemic that affects the entire world are the basis for consideration of the adjustment of related standards. The purpose of this study is to look at the standards for natural ventilation in several countries, namely the United States, Singapore, Malaysia, and Australia, as well as identify criteria that can be applied according to conditions in Indonesia. The results showed that the need for natural ventilation in buildings in Indonesia by 5% has met the existing conditions. However, further studies regarding the need for natural ventilation that are adjusted based on the function of the room as determined by ASHRAE 62.1 need to be carried out.","PeriodicalId":31886,"journal":{"name":"Rekayasa Sipil","volume":"17 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rekayasa Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21776/ub.rekayasasipil.2023.017.02.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Indonesian National Standard (SNI) 6572:2001 on natural ventilation in buildings has not been updated in the last 20 years, while similar standards in other countries have been periodically improved. The development of science and technology, environmental conditions, coupled with the COVID-19 pandemic that affects the entire world are the basis for consideration of the adjustment of related standards. The purpose of this study is to look at the standards for natural ventilation in several countries, namely the United States, Singapore, Malaysia, and Australia, as well as identify criteria that can be applied according to conditions in Indonesia. The results showed that the need for natural ventilation in buildings in Indonesia by 5% has met the existing conditions. However, further studies regarding the need for natural ventilation that are adjusted based on the function of the room as determined by ASHRAE 62.1 need to be carried out.
研究建筑物的自然通风需求
印度尼西亚国家标准(SNI) 6572:2001关于建筑物自然通风的标准在过去20年中没有更新,而其他国家的类似标准则定期改进。科技发展、环境条件以及影响全球的新冠肺炎疫情是考虑调整相关标准的依据。本研究的目的是考察几个国家的自然通风标准,即美国、新加坡、马来西亚和澳大利亚,并根据印度尼西亚的情况确定可适用的标准。结果表明,印尼建筑自然通风需求减少5%已满足现有条件。然而,需要对根据ASHRAE 62.1确定的房间功能进行调整的自然通风需求进行进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书