Measurement and Analysis of Radio-frequency Radiation Exposure Level from Different Mobile Base Transceiver Stations in Ajaokuta and Environs, Nigeria

P. Ushie, V. Nwankwo, Ayinmode Bolaji, O. D. Osahun
{"title":"Measurement and Analysis of Radio-frequency Radiation Exposure Level from Different Mobile Base Transceiver Stations in Ajaokuta and Environs, Nigeria","authors":"P. Ushie, V. Nwankwo, Ayinmode Bolaji, O. D. Osahun","doi":"10.9790/4961-0361721","DOIUrl":null,"url":null,"abstract":"We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs. The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of other factors, including wave interference from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is below the standard limit (4.5W/sqm for 900MHz and 9W/sqm for 18000MHz) set by the International Commission on Non-ionizing Radiation Protection (ICNIRP) and other regulatory agencies.","PeriodicalId":8462,"journal":{"name":"arXiv: Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv: Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9790/4961-0361721","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs. The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of other factors, including wave interference from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is below the standard limit (4.5W/sqm for 900MHz and 9W/sqm for 18000MHz) set by the International Commission on Non-ionizing Radiation Protection (ICNIRP) and other regulatory agencies.
尼日利亚Ajaokuta和周边地区不同移动基站收发信台射频辐射暴露水平的测量和分析
我们提出了对ajajokuta周围选定的移动基站的射频辐射暴露的初步评估结果。测量径向距离125m范围内射频辐射的功率密度。虽然由于其他因素的影响,包括参考基站周围其他电磁源的波干扰,数值有所波动,但我们从分析中发现,辐射暴露水平低于国际非电离辐射防护委员会(ICNIRP)和其他监管机构设定的标准限值(900MHz时为4.5W/平方米,18000MHz时为9W/平方米)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信