Andrés Mauricio Oviedo Pinzón, P. M. Silveira, J. M. de Carvalho Filho
{"title":"Improvements of power quality in a microgrid when using LCL filters at VSCs","authors":"Andrés Mauricio Oviedo Pinzón, P. M. Silveira, J. M. de Carvalho Filho","doi":"10.1109/ICHQP.2018.8378830","DOIUrl":null,"url":null,"abstract":"Measurements based in the IEEE Std 1459–2010 can show the need of applying filters in a microgrid to attend the IEEE Std 1547–2003 requirements related to harmonic pollution in order to maintain the power quality limits. LCL-filters placed on the existing voltage source converters can improve the microgrid power quality, reducing the harmonic pollution in it. This paper applies a design procedure of LCL-filters and the control adjustments on voltage source converters to reduce the harmonic current injected to levels accepted by the IEEE Std 1547–2003. Later, compares measurements under IEEE Std 1459-2010 before and after the LCL-Filters addition to show the reduction of harmonic currents in the microgrid.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"63 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378830","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Measurements based in the IEEE Std 1459–2010 can show the need of applying filters in a microgrid to attend the IEEE Std 1547–2003 requirements related to harmonic pollution in order to maintain the power quality limits. LCL-filters placed on the existing voltage source converters can improve the microgrid power quality, reducing the harmonic pollution in it. This paper applies a design procedure of LCL-filters and the control adjustments on voltage source converters to reduce the harmonic current injected to levels accepted by the IEEE Std 1547–2003. Later, compares measurements under IEEE Std 1459-2010 before and after the LCL-Filters addition to show the reduction of harmonic currents in the microgrid.