Gustavo Silvano, H. Rachadel, M. Dalmas, C. Dutra, M. Zapella
{"title":"Considerations on the application of PTPv2 over a PRP network","authors":"Gustavo Silvano, H. Rachadel, M. Dalmas, C. Dutra, M. Zapella","doi":"10.1109/TDC.2016.7520044","DOIUrl":null,"url":null,"abstract":"Power grid advances in the last years allowed new distributed applications developments. In this context, time synchronization is a very important issue, as many applications need to achieve high synchronization accuracy. The IEEE 1588-2008 standard [2] defines the second version of PTP, designed to achieve clock accuracy in the sub-microsecond range. In these scenarios Ethernet network redundancy is also important to assure system availability and fault robustness. PRP, defined in the IEC 62439-3 Ed. 3 [3], is designed to improve robustness to network failures with zero-time recovery. This paper describes the challenges of a PTPv2 implementation in a PRP network and also presents the tests and results when using these protocols in a real case scenario.","PeriodicalId":6497,"journal":{"name":"2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"10 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2016.7520044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Power grid advances in the last years allowed new distributed applications developments. In this context, time synchronization is a very important issue, as many applications need to achieve high synchronization accuracy. The IEEE 1588-2008 standard [2] defines the second version of PTP, designed to achieve clock accuracy in the sub-microsecond range. In these scenarios Ethernet network redundancy is also important to assure system availability and fault robustness. PRP, defined in the IEC 62439-3 Ed. 3 [3], is designed to improve robustness to network failures with zero-time recovery. This paper describes the challenges of a PTPv2 implementation in a PRP network and also presents the tests and results when using these protocols in a real case scenario.