Second Law Analysis of a Stirling Cryocooler With Optimal Design of the Regenerator and Losses

E. Rogdakis, N. A. Bormpilas
{"title":"Second Law Analysis of a Stirling Cryocooler With Optimal Design of the Regenerator and Losses","authors":"E. Rogdakis, N. A. Bormpilas","doi":"10.1115/imece2001/pid-25621","DOIUrl":null,"url":null,"abstract":"\n The aim of the research in this paper is a second law analysis of a Stirling cryocooler. A one-dimensional model is proposed for the simulation of the gas flow in the expansion space, the regenerator, the warm-end, the compression space and the compressor. Helium gas is selected as the working medium. An algorithm has been developed considering parametrically the most from the main operational tasks of the thermodynamic cycle.\n Performance indices such as heat input, efficiency, external dimensions of the engine and technical requirements are taken into account as constraints. Engine operating parameters i.e. speed, external temperature, mean pressure are fixed. The regenerator loss has a critical influence on the cryocooler efficiency and the reduction of this kind of internal irreversibilities is extremely difficult due to the generator is subject to rapidly cycling flows accompanied by steep temperature gradients and large pressure variations.\n The second flow analysis of the regenerator identifies two principal losses, the irreversible internal heat transfer into the solid matrix and the hydraulic resistance. An optimization technique leads to entropy generation charts, extremely useful for a good design of the regenerator.\n Finally the main thermodynamic characteristics (net refrigeration, power input and the coefficient of performance) of the cryocooler are given both cases with and without external and internal irreversibilities.","PeriodicalId":9805,"journal":{"name":"Chemical and Process Industries","volume":"54 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2001-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical and Process Industries","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2001/pid-25621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the research in this paper is a second law analysis of a Stirling cryocooler. A one-dimensional model is proposed for the simulation of the gas flow in the expansion space, the regenerator, the warm-end, the compression space and the compressor. Helium gas is selected as the working medium. An algorithm has been developed considering parametrically the most from the main operational tasks of the thermodynamic cycle. Performance indices such as heat input, efficiency, external dimensions of the engine and technical requirements are taken into account as constraints. Engine operating parameters i.e. speed, external temperature, mean pressure are fixed. The regenerator loss has a critical influence on the cryocooler efficiency and the reduction of this kind of internal irreversibilities is extremely difficult due to the generator is subject to rapidly cycling flows accompanied by steep temperature gradients and large pressure variations. The second flow analysis of the regenerator identifies two principal losses, the irreversible internal heat transfer into the solid matrix and the hydraulic resistance. An optimization technique leads to entropy generation charts, extremely useful for a good design of the regenerator. Finally the main thermodynamic characteristics (net refrigeration, power input and the coefficient of performance) of the cryocooler are given both cases with and without external and internal irreversibilities.
斯特林制冷机蓄热器及损耗优化的第二定律分析
本文的研究目的是对斯特林制冷机的第二定律进行分析。提出了一维气体在膨胀空间、蓄热器、暖端、压缩空间和压缩机内流动的模拟模型。选择氦气作为工质。从热力学循环的主要操作任务出发,提出了一种考虑参数化的算法。性能指标,如热输入,效率,发动机的外部尺寸和技术要求被考虑为约束。发动机运行参数,即速度,外部温度,平均压力是固定的。蓄热器损失对制冷机效率有重要影响,由于蓄热器处于快速循环流动中,且温度梯度大、压力变化大,因此降低这种内部不可逆性极为困难。再生器的第二个流动分析确定了两个主要损失,不可逆的内部热量传递到固体基质和水力阻力。一种优化技术可以生成熵生成图,这对再生器的良好设计非常有用。最后给出了冷冻机的主要热力学特性(净制冷量、功率输入和性能系数),以及有无外部不可逆和内部不可逆的情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信