Study on infrared radiation characteristic of heat-sensitive acupoints in bronchial asthma

N. Tian, Bing Xi, Bi-Ying Su, Ri-Xin Chen
{"title":"Study on infrared radiation characteristic of heat-sensitive acupoints in bronchial asthma","authors":"N. Tian, Bing Xi, Bi-Ying Su, Ri-Xin Chen","doi":"10.1109/BIBMW.2011.6112470","DOIUrl":null,"url":null,"abstract":"Objective : Study the infrared radiation characteristic of heat-sensitive acupoints in bronchial asthma. Method: Apply Thermal Texture Mapping System (TSI-21) to study the infrared radiation characteristic of heat-sensitive acupoints on the body surfaces of 54 bronchial asthma patients. Set control areas on the back of the patient and 4 separate control points, each in the width of 3cm respectively at the left, right, upper and lower section of the acupoint. Apply two observation indicators, respectively the absolute infrared radiant intensity (temperature) and relative infrared radiant intensity (differential value between the radiant intensity of the control point and the overall radiant intensity), and compare the value of infrared radiant intensity measured at heat-sensitive acupoints and control points/areas. Result: The average temperature of heat-sensitive acupoints in 54 bronchial asthma patients measured at 31.15°C, which indicated that the differential value between the radiant intensity of heat-sensitive acupoints and the overall radiant intensity was significant (P<0.05); Mean whilst, the difference between the temperature of heat-sensitive acupoint and control point was not significant (P> 0.05); however, the difference between the average temperature of heat-sensitive acupoints and the average temperature of the control points on the back of the patient was significant (P<0.05). Conclusion : Heat-sensitive acupoints are featured with high-level infrared radiant intensity; therefore, a certain area of enhanced infrared radiant intensity can be formed around the heat-sensitive acupoint.","PeriodicalId":6345,"journal":{"name":"2011 IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW)","volume":"91 1","pages":"773-777"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIBMW.2011.6112470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective : Study the infrared radiation characteristic of heat-sensitive acupoints in bronchial asthma. Method: Apply Thermal Texture Mapping System (TSI-21) to study the infrared radiation characteristic of heat-sensitive acupoints on the body surfaces of 54 bronchial asthma patients. Set control areas on the back of the patient and 4 separate control points, each in the width of 3cm respectively at the left, right, upper and lower section of the acupoint. Apply two observation indicators, respectively the absolute infrared radiant intensity (temperature) and relative infrared radiant intensity (differential value between the radiant intensity of the control point and the overall radiant intensity), and compare the value of infrared radiant intensity measured at heat-sensitive acupoints and control points/areas. Result: The average temperature of heat-sensitive acupoints in 54 bronchial asthma patients measured at 31.15°C, which indicated that the differential value between the radiant intensity of heat-sensitive acupoints and the overall radiant intensity was significant (P<0.05); Mean whilst, the difference between the temperature of heat-sensitive acupoint and control point was not significant (P> 0.05); however, the difference between the average temperature of heat-sensitive acupoints and the average temperature of the control points on the back of the patient was significant (P<0.05). Conclusion : Heat-sensitive acupoints are featured with high-level infrared radiant intensity; therefore, a certain area of enhanced infrared radiant intensity can be formed around the heat-sensitive acupoint.
支气管哮喘热敏感穴位红外辐射特征的研究
目的:研究支气管哮喘热敏感穴位的红外辐射特征。方法:应用热纹理映射系统(TSI-21)对54例支气管哮喘患者体表热敏穴位的红外辐射特征进行研究。在患者背部设置控制区,在穴位的左、右、上、下分别设置4个独立控制点,每个控制点宽度为3cm。应用绝对红外辐射强度(温度)和相对红外辐射强度(控制点辐射强度与整体辐射强度的差值)两个观察指标,比较热敏穴位和控制点/区域测量的红外辐射强度值。结果:54例支气管哮喘患者热敏穴平均温度为31.15℃,热敏穴辐射强度与整体辐射强度差值有统计学意义(P < 0.05);而热敏感穴的平均温度与患者背部控制点的平均温度差异有统计学意义(P<0.05)。结论:热敏感穴位具有高红外辐射强度的特点;因此,可以在热敏穴位周围形成一定区域的红外辐射强度增强。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信