{"title":"Radiofrequency modulation in the Thoneman ion source","authors":"J. Erö","doi":"10.1016/0369-643X(58)90011-2","DOIUrl":null,"url":null,"abstract":"<div><p>A fast energy analyser using a scintillation detector has been made which is able to trace the spectrum in 20 μs. It is shown that the ion beam has r.f. modulation of about 50 eV. A demodulating r.f. field after the exit channel eliminates this modulation if the ions pass through it at right phase, and thus the energy spread of the beam is diminished below 10 eV. By determining the time of flight of ions from the r.f. modulation to the demodulating field the conclusion was drawn that the r.f. modulation occurs immediately near the cathode.</p></div>","PeriodicalId":100970,"journal":{"name":"Nuclear Instruments","volume":"3 5","pages":"Pages 303-306"},"PeriodicalIF":0.0000,"publicationDate":"1958-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0369-643X(58)90011-2","citationCount":"29","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0369643X58900112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

Abstract

A fast energy analyser using a scintillation detector has been made which is able to trace the spectrum in 20 μs. It is shown that the ion beam has r.f. modulation of about 50 eV. A demodulating r.f. field after the exit channel eliminates this modulation if the ions pass through it at right phase, and thus the energy spread of the beam is diminished below 10 eV. By determining the time of flight of ions from the r.f. modulation to the demodulating field the conclusion was drawn that the r.f. modulation occurs immediately near the cathode.

Thoneman离子源的射频调制
利用闪烁探测器研制了一种能在20 μs范围内跟踪光谱的快速能量分析仪。结果表明,该离子束具有约50 eV的射频调制。如果离子以正确的相位通过出口通道后的解调射频场,则消除了这种调制,从而使光束的能量扩散减少到10 eV以下。通过测定离子从射频调制到解调场的飞行时间,得出射频调制直接发生在阴极附近的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信