50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes

Khorolsuren Tuvshinbayar, Guido Ehrmann, A. Ehrmann
{"title":"50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes","authors":"Khorolsuren Tuvshinbayar, Guido Ehrmann, A. Ehrmann","doi":"10.3390/textiles2020014","DOIUrl":null,"url":null,"abstract":"The electrocardiogram (ECG) is one of the most commonly measured biosignals. In particular, textile electrodes allow for the measuring of long-term ECG without skin irritation or other discomforts for the patient. Such textile electrodes, however, usually suffer from insufficient or unreliable skin contact. Thus, developing textile electrodes is impeded by the often-complicated differentiation between signal artifacts due to moving and breathing and artifacts related to unreliable skin contact. Here, we suggest a simple method of using 50/60 Hz power grid noise to evaluate the skin contact of different textile electrodes in comparison with commercial glued electrodes. We use this method to show the drying of wetted skin under an embroidered electrode as well as sweating of the originally dry skin under a coated electrode with high water vapor resistance.","PeriodicalId":94219,"journal":{"name":"Textiles (Basel, Switzerland)","volume":"60 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Textiles (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/textiles2020014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The electrocardiogram (ECG) is one of the most commonly measured biosignals. In particular, textile electrodes allow for the measuring of long-term ECG without skin irritation or other discomforts for the patient. Such textile electrodes, however, usually suffer from insufficient or unreliable skin contact. Thus, developing textile electrodes is impeded by the often-complicated differentiation between signal artifacts due to moving and breathing and artifacts related to unreliable skin contact. Here, we suggest a simple method of using 50/60 Hz power grid noise to evaluate the skin contact of different textile electrodes in comparison with commercial glued electrodes. We use this method to show the drying of wetted skin under an embroidered electrode as well as sweating of the originally dry skin under a coated electrode with high water vapor resistance.
50/ 60hz电网噪声对纺织ECG电极皮肤接触的影响
心电图(ECG)是最常用的测量生物信号之一。特别是,纺织电极允许长期心电图的测量没有皮肤刺激或其他不适的病人。然而,这种纺织电极通常受到皮肤接触不足或不可靠的影响。因此,由于运动和呼吸引起的信号伪影和与不可靠的皮肤接触有关的伪影之间的复杂区分,阻碍了纺织品电极的发展。在这里,我们提出了一种简单的方法,使用50/60 Hz电网噪声来评估不同纺织品电极与商业粘合电极的皮肤接触。我们用这种方法显示了在刺绣电极下潮湿皮肤的干燥,以及在具有高水蒸气阻力的涂层电极下原本干燥的皮肤的出汗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信