Impact of environmental tobacco smoke on the water adsorption capacity of desiccant materials

Song-Yng Lee , Tushar K. Ghosh , Anthony L. Hines , Davor Novosel
{"title":"Impact of environmental tobacco smoke on the water adsorption capacity of desiccant materials","authors":"Song-Yng Lee ,&nbsp;Tushar K. Ghosh ,&nbsp;Anthony L. Hines ,&nbsp;Davor Novosel","doi":"10.1016/0950-4214(95)00015-4","DOIUrl":null,"url":null,"abstract":"<div><p>The water adsorption capacity of desiccant materials may be affected significantly if particulates are present in the air that is to be processed. Air containing environmental tobacco smoke was used to study the effect of particulates. A smoking apparatus was designed by simulating the puffing of a cigarette by a person to generate environmental tobacco smoke. The apparatus can take a puff from a cigarette at 1 min intervals; one puff requires 2 s and entails drawing a total of 35 cm<sup>3</sup> of air through the cigarette. The puffing process was controlled by a computer. The sidestream smoke generated during the idle burning of the cigarette in the 1 min interval between puffs was diluted with the room air to produce the environmental tobacco smoke and was used in all the experiments. Desiccants used in the present work included silica gel and molecular sieve 13X. Experiments were carried out under dynamic conditions using a packed bed adsorber at 298 K and at a relative humidity of ≈50%. The adsorption and regeneration cycles were repeated 15 times using the same adsorbent. Significant amounts of hydrocarbons and particulates were removed by both silica gel and the molecular sieve during the initial period of a run. The equilibrium water uptake capacity of silica gel at higher relative humidities decreased significantly after 15 cycles but that of the molecular sieve remained almost the same as that of a fresh sample. Also, a molecular sieve that was exposed to tobacco smoke could be regenerated at a lower temperature than the exposed silica gel.</p></div>","PeriodicalId":12586,"journal":{"name":"Gas Separation & Purification","volume":"9 4","pages":"Pages 285-291"},"PeriodicalIF":0.0000,"publicationDate":"1995-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0950-4214(95)00015-4","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gas Separation & Purification","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0950421495000154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The water adsorption capacity of desiccant materials may be affected significantly if particulates are present in the air that is to be processed. Air containing environmental tobacco smoke was used to study the effect of particulates. A smoking apparatus was designed by simulating the puffing of a cigarette by a person to generate environmental tobacco smoke. The apparatus can take a puff from a cigarette at 1 min intervals; one puff requires 2 s and entails drawing a total of 35 cm3 of air through the cigarette. The puffing process was controlled by a computer. The sidestream smoke generated during the idle burning of the cigarette in the 1 min interval between puffs was diluted with the room air to produce the environmental tobacco smoke and was used in all the experiments. Desiccants used in the present work included silica gel and molecular sieve 13X. Experiments were carried out under dynamic conditions using a packed bed adsorber at 298 K and at a relative humidity of ≈50%. The adsorption and regeneration cycles were repeated 15 times using the same adsorbent. Significant amounts of hydrocarbons and particulates were removed by both silica gel and the molecular sieve during the initial period of a run. The equilibrium water uptake capacity of silica gel at higher relative humidities decreased significantly after 15 cycles but that of the molecular sieve remained almost the same as that of a fresh sample. Also, a molecular sieve that was exposed to tobacco smoke could be regenerated at a lower temperature than the exposed silica gel.

环境烟草烟雾对干燥剂材料吸水能力的影响
如果待处理的空气中存在颗粒,干燥剂材料的吸水能力可能会受到显著影响。以含环境烟草烟雾的空气为研究对象,研究了颗粒物的影响。设计了一种模拟人吸烟产生环境烟雾的吸烟装置。该装置可以每隔1分钟吸一口烟;吸一口烟需要2秒,总共需要吸入35立方厘米的空气。膨化过程由计算机控制。将卷烟怠燃间隔1 min时产生的侧流烟与室内空气稀释,产生环境烟草烟雾,并用于所有实验。本研究使用的干燥剂包括硅胶和分子筛13X。实验采用填充床吸附器,在298 K、相对湿度≈50%的动态条件下进行。使用相同的吸附剂,重复15次吸附和再生循环。在运行的初始阶段,硅胶和分子筛可以去除大量的碳氢化合物和颗粒。15次循环后,硅胶在较高相对湿度下的平衡吸水能力显著下降,而分子筛的平衡吸水能力与新鲜样品的平衡吸水能力基本保持一致。此外,暴露于烟草烟雾中的分子筛可以在比暴露的硅胶更低的温度下再生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信