A comparison of typical non-invasive method for utility harmonic impedance estimation

Xian Zheng, Yamei Liu, Fei-Yu Chen, Shuangting Xu, Xianyong Xiao
{"title":"A comparison of typical non-invasive method for utility harmonic impedance estimation","authors":"Xian Zheng, Yamei Liu, Fei-Yu Chen, Shuangting Xu, Xianyong Xiao","doi":"10.1109/ICHQP.2018.8378914","DOIUrl":null,"url":null,"abstract":"The proliferation of power electronic equipment brings lots of problems to the power system, one of them is harmonic. Harmonic impedance is an essential parameter to evaluate the harmonic emission level and distinguish the harmonic responsibility when the harmonic level exceeds planning levels. At present, there are a lot of methods to estimate utility harmonic impedance, divided into invasive method and non-invasive method. In this paper, some typical non-invasive methods have been compared, and the simulation system is built in the MATLAB. The background harmonic fluctuation and the different values of utility and customer harmonic impedances are considered to evaluate the performance of the typical non-invasive methods. The simulation results proved that the complex ICA method is the most robust to the background harmonic fluctuation than other methods, but in some special cases, the method based on data selection has a better performance.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"58 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378914","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

The proliferation of power electronic equipment brings lots of problems to the power system, one of them is harmonic. Harmonic impedance is an essential parameter to evaluate the harmonic emission level and distinguish the harmonic responsibility when the harmonic level exceeds planning levels. At present, there are a lot of methods to estimate utility harmonic impedance, divided into invasive method and non-invasive method. In this paper, some typical non-invasive methods have been compared, and the simulation system is built in the MATLAB. The background harmonic fluctuation and the different values of utility and customer harmonic impedances are considered to evaluate the performance of the typical non-invasive methods. The simulation results proved that the complex ICA method is the most robust to the background harmonic fluctuation than other methods, but in some special cases, the method based on data selection has a better performance.
公用事业谐波阻抗非侵入估计方法的比较
电力电子设备的激增给电力系统带来了许多问题,其中之一就是谐波问题。谐波阻抗是评价谐波发射水平和在谐波水平超过规划水平时区分谐波责任的重要参数。目前,实用谐波阻抗的估计方法很多,分为侵入式和非侵入式两种。本文对几种典型的无创方法进行了比较,并在MATLAB中搭建了仿真系统。考虑了背景谐波波动以及电力公司和客户谐波阻抗的不同值,对典型的无创方法进行了性能评价。仿真结果表明,复合ICA方法对背景谐波波动的鲁棒性优于其他方法,但在某些特殊情况下,基于数据选择的方法具有更好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信