The effect of minimal and high flow anesthesia on optic nerve sheath diameter in laparotomic gynecological surgery

A. Onur, T. Onur, Ü. Karaca, H. Sayan, Canan Yılmaz, Nermin Kılıçarslan
{"title":"The effect of minimal and high flow anesthesia on optic nerve sheath diameter in laparotomic gynecological surgery","authors":"A. Onur, T. Onur, Ü. Karaca, H. Sayan, Canan Yılmaz, Nermin Kılıçarslan","doi":"10.28982/josam.1123380","DOIUrl":null,"url":null,"abstract":"Background/Aim: Optic nerve sheath diameter (ONSD) is a surrogate parameter for intracranial pressure. This study evaluated the effect of anesthetics on ONSD in women undergoing surgery. We aimed to measure the effect of minimal and high flow anesthesia techniques on expiratory/inspiratory oxygen and carbon dioxide fraction values, hemodynamic parameters, and the optic nerve sheath diameter by ultrasonography in open gynecological surgeries. \nMethods: In the present prospective cohort study, 80 patients who planned laparotomic gynecological surgery were divided into two groups: a high flow of 2 L/min and a minimum flow of 0.5 L/min. Anesthesia was maintained with 50% oxygen-50% air at 2 L/min and desflurane at 1.1 MAC in Group 1 (n=40) and 50% oxygen-50% air at 0.5 L/min and desflurane at 1.1 MAC in Group 2 (n=40). After 10–15 min, group 2 was administered minimal flow with 50–60% oxygen and 40–50% air at 0.5 L/min desflurane, and 10 min before the end of the surgery, the patients were switched to high flow with 50% oxygen-50% air at 2 L/min. \nResults: Decreasing heart rates were higher in Group 2 (T0 P=0.001, T2 P=0.007, T3 P=0.035). There was a significant positive correlation between EtCO2 at the 60th min and optic nerve sheath diameter measurements in the minimal flow group (left ONSD r=0.440, P=0.004, right ONSD r=0.473, P=0.002). Although inspiratory oxygen values in Group 2 did not fall below 32%, it was lower than Group 1 except for the last measurement time. \nConclusion: Minimal flow anesthesia is as safe as high flow in terms of effects on optic nerve sheath diameter and oxygenation parameters in laparotomic gynecological surgery.","PeriodicalId":30878,"journal":{"name":"International Journal of Surgery and Medicine","volume":"14 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Surgery and Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.28982/josam.1123380","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Aim: Optic nerve sheath diameter (ONSD) is a surrogate parameter for intracranial pressure. This study evaluated the effect of anesthetics on ONSD in women undergoing surgery. We aimed to measure the effect of minimal and high flow anesthesia techniques on expiratory/inspiratory oxygen and carbon dioxide fraction values, hemodynamic parameters, and the optic nerve sheath diameter by ultrasonography in open gynecological surgeries. Methods: In the present prospective cohort study, 80 patients who planned laparotomic gynecological surgery were divided into two groups: a high flow of 2 L/min and a minimum flow of 0.5 L/min. Anesthesia was maintained with 50% oxygen-50% air at 2 L/min and desflurane at 1.1 MAC in Group 1 (n=40) and 50% oxygen-50% air at 0.5 L/min and desflurane at 1.1 MAC in Group 2 (n=40). After 10–15 min, group 2 was administered minimal flow with 50–60% oxygen and 40–50% air at 0.5 L/min desflurane, and 10 min before the end of the surgery, the patients were switched to high flow with 50% oxygen-50% air at 2 L/min. Results: Decreasing heart rates were higher in Group 2 (T0 P=0.001, T2 P=0.007, T3 P=0.035). There was a significant positive correlation between EtCO2 at the 60th min and optic nerve sheath diameter measurements in the minimal flow group (left ONSD r=0.440, P=0.004, right ONSD r=0.473, P=0.002). Although inspiratory oxygen values in Group 2 did not fall below 32%, it was lower than Group 1 except for the last measurement time. Conclusion: Minimal flow anesthesia is as safe as high flow in terms of effects on optic nerve sheath diameter and oxygenation parameters in laparotomic gynecological surgery.
小流量和高流量麻醉对剖腹妇科手术视神经鞘直径的影响
背景/目的:视神经鞘直径(ONSD)是颅内压的替代参数。本研究评估了麻醉药物对手术妇女ONSD的影响。我们旨在通过超声测量小流量和高流量麻醉技术对开放妇科手术中呼气/吸气氧和二氧化碳分数值、血流动力学参数和视神经鞘直径的影响。方法:在本前瞻性队列研究中,将80例计划剖腹妇科手术的患者分为高流量2 L/min和最小流量0.5 L/min两组。第1组(n=40)维持50%氧-50%空气2l /min,地氟醚1.1 MAC麻醉;第2组(n=40)维持50%氧-50%空气0.5 L/min,地氟醚1.1 MAC麻醉。10 - 15 min后,组2给予50-60%氧气+ 40-50%空气0.5 L/min地氟醚的小流量,手术结束前10 min切换至50%氧气-50%空气2 L/min的大流量。结果:2组降低心率明显高于对照组(T0 P=0.001, T2 P=0.007, T3 P=0.035)。最小血流组60 min EtCO2与视神经鞘直径测量值有显著正相关(左ONSD r=0.440, P=0.004,右ONSD r=0.473, P=0.002)。2组吸入氧值虽未低于32%,但除最后一次测量时间外均低于1组。结论:在剖腹妇科手术中,小流量麻醉对视神经鞘直径和氧合参数的影响与大流量麻醉一样安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
57
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信