{"title":"Low-frequency parametric ultrasound imaging using pulse compression with maximum-length sequence excitation","authors":"H. Nomura, Riku Nishioka","doi":"10.1121/2.0000840","DOIUrl":null,"url":null,"abstract":"In the present study, to realize low-frequency ultrasound (US) imaging, the application of maximum-length sequence (M-sequence) to the compressed parametric US is attempted to reduce time sidelobes, and the performance is experimentally discussed. A modulated primary US at a carrier frequency of 2.8 MHz was radiated in water to generate a 400-kHz parametric US coded by an M-sequence with a chip length equal to one cycle of a 400-kHz signal, and brass rods were used as targets. Experimental results showed that the pulse compression of parametric US with M-sequence reduced artifacts in image. Moreover, the lateral resolution obtained by the proposed method was improved in comparison with that obtained by the compressed-chirped parametric US with the bandwidth from 100 to 500 kHz. These results suggest that the application of M-sequence is well-suited for the parametric US imaging with improved artifacts and lateral resolution.","PeriodicalId":20469,"journal":{"name":"Proc. Meet. Acoust.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proc. Meet. Acoust.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1121/2.0000840","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the present study, to realize low-frequency ultrasound (US) imaging, the application of maximum-length sequence (M-sequence) to the compressed parametric US is attempted to reduce time sidelobes, and the performance is experimentally discussed. A modulated primary US at a carrier frequency of 2.8 MHz was radiated in water to generate a 400-kHz parametric US coded by an M-sequence with a chip length equal to one cycle of a 400-kHz signal, and brass rods were used as targets. Experimental results showed that the pulse compression of parametric US with M-sequence reduced artifacts in image. Moreover, the lateral resolution obtained by the proposed method was improved in comparison with that obtained by the compressed-chirped parametric US with the bandwidth from 100 to 500 kHz. These results suggest that the application of M-sequence is well-suited for the parametric US imaging with improved artifacts and lateral resolution.
脉冲压缩与最大长度序列激励的低频参数超声成像
为了实现低频超声成像,本文尝试将最大长度序列(m序列)应用于压缩的参数超声,以减少时间副瓣,并对其性能进行了实验讨论。将载波频率为2.8 MHz的调制主US在水中辐射,产生400-kHz参数US,该US采用m序列编码,芯片长度等于400-kHz信号的一个周期。实验结果表明,采用m序列对参数化US进行脉冲压缩可以减少图像中的伪影。此外,与带宽为100 ~ 500 kHz的压缩啁啾参数US相比,该方法获得的横向分辨率有所提高。这些结果表明,m序列的应用非常适合于参数化超声成像,具有更好的伪影和横向分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信