{"title":"Reliability Evaluation of Kumpai Feeder Distribution System at PT. PLN (Persero) ULP Siantan","authors":"A. Kurniawan, F. Fitriah, M. Arsyad","doi":"10.26418/elkha.v13i2.48660","DOIUrl":null,"url":null,"abstract":"The research on reliability index of a feeder aims to evaluate the reliability level of a feeder using the Reliability Index Assessment (RIA) method. This method evaluates the reliability of a 20 kV distribution network by calculating the reliability indexes of each load point. The evaluation results show the reliability index value per section of the Kumpai Feeder at PT. PLN (Persero) ULP Siantan within one year. The SAIFI values are 0.0092; 0.0012; 12,477; 0.0596; 0.0204; 0.0470; 0.0155; 0.0728, the SAIDI values are 0.0277; 0.0042; 37,746; 0.1862; 0.0741; 0.1524; 0.0493; 0.2209, the CAIDI values are 3.0108; 3.5; 3,025; 3.1241; 3.6323; 3.2425; 3.1806; 3.0343, the MAIFI values are 0; 5,480; 0.2145; 0.0020; 0.0038; 0.0042; 0.0006; 0.0014. The calculation results show that the 20 kV distribution system at PT. PLN (Persero) ULP Siantan at the Kumpai Feeder can be categorized as unreliable. Because the SAIFI value of this feeder exceeds the standard set by PT. PLN (Persero) which are 12.477 times/customer/year and 3.2 times/customer/year, respectively. The factors affecting the reliability index of the Kumpai feeder are the number and duration of blackouts, the number of customers, and the length of the distribution system channel.","PeriodicalId":32754,"journal":{"name":"Elkha Jurnal Teknik Elektro","volume":"79 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elkha Jurnal Teknik Elektro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26418/elkha.v13i2.48660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The research on reliability index of a feeder aims to evaluate the reliability level of a feeder using the Reliability Index Assessment (RIA) method. This method evaluates the reliability of a 20 kV distribution network by calculating the reliability indexes of each load point. The evaluation results show the reliability index value per section of the Kumpai Feeder at PT. PLN (Persero) ULP Siantan within one year. The SAIFI values are 0.0092; 0.0012; 12,477; 0.0596; 0.0204; 0.0470; 0.0155; 0.0728, the SAIDI values are 0.0277; 0.0042; 37,746; 0.1862; 0.0741; 0.1524; 0.0493; 0.2209, the CAIDI values are 3.0108; 3.5; 3,025; 3.1241; 3.6323; 3.2425; 3.1806; 3.0343, the MAIFI values are 0; 5,480; 0.2145; 0.0020; 0.0038; 0.0042; 0.0006; 0.0014. The calculation results show that the 20 kV distribution system at PT. PLN (Persero) ULP Siantan at the Kumpai Feeder can be categorized as unreliable. Because the SAIFI value of this feeder exceeds the standard set by PT. PLN (Persero) which are 12.477 times/customer/year and 3.2 times/customer/year, respectively. The factors affecting the reliability index of the Kumpai feeder are the number and duration of blackouts, the number of customers, and the length of the distribution system channel.
Siantan PT. PLN (Persero) ULP Kumpai馈线分配系统可靠性评估
馈线可靠性指标研究的目的是利用可靠性指标评估(RIA)方法对馈线的可靠性水平进行评价。该方法通过计算各负荷点的可靠性指标,对20kv配电网进行可靠性评价。评估结果显示了Siantan PT. PLN (Persero) ULP Kumpai馈线一年内每段的可靠性指标值。SAIFI值为0.0092;0.0012;12477;0.0596;0.0204;0.0470;0.0155;0.0728, SAIDI值为0.0277;0.0042;37746;0.1862;0.0741;0.1524;0.0493;0.2209, CAIDI值为3.0108;3.5;3025;3.1241;3.6323;3.2425;3.1806;3.0343, MAIFI值为0;5480;0.2145;0.0020;0.0038;0.0042;0.0006;0.0014. 计算结果表明,Kumpai馈线上PT. PLN (Persero) ULP Siantan的20kv配电系统可归类为不可靠。因为该馈线的SAIFI值超过了PT. PLN (Persero)设定的标准,分别是12.477次/客户/年和3.2次/客户/年。影响Kumpai馈线可靠性指标的因素有停电次数和停电持续时间、用户数量和配电系统通道长度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
23
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信