Eugenia A. Lapina, S. Zverev, Sergey V. Andreev, K. A. Sakharov
{"title":"Determination of chlorine-containing compounds in disinfectants using ion-exchange chromatography","authors":"Eugenia A. Lapina, S. Zverev, Sergey V. Andreev, K. A. Sakharov","doi":"10.32362/2410-6593-2023-18-3-254-264","DOIUrl":null,"url":null,"abstract":"Objectives. To develop a method for the determination of hypochlorite, chloride, chlorite, chlorate, and perchlorate ions in solution; to determine the limits of detection and quantitation for ClO−, Cl−, ClO2−, ClO3−, and ClO4− ions; to evaluate the applicability of the developed method and its suitability for disinfectant analysis.Methods. Ionic chromatography using a conductometric detection system in isocratic elution mode.Results. The method developed for chromatographic determination of chlorine-containing ions can be used to quantify the content of hypochlorite, chloride, chlorite, chlorate, and perchlorate ions. In isocratic elution mode at 7.5 mM NaOH and a flow rate of 0.4 mL/min, the content of chlorine-containing ions can be determined with high sensitivity. The presented method does not require the use of expensive equipment for the ultrasensitive analysis of the studied compounds.Conclusions. A novel method for the simultaneous determination of hypochlorite, chloride, chlorite, chlorate, and perchlorate ions in case of their combined presence is proposed. The technique can be used to carry out routine control of the content of these disinfectant components during use, increasing their effectiveness at the same time as managing associated toxicological risks.","PeriodicalId":12215,"journal":{"name":"Fine Chemical Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fine Chemical Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32362/2410-6593-2023-18-3-254-264","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives. To develop a method for the determination of hypochlorite, chloride, chlorite, chlorate, and perchlorate ions in solution; to determine the limits of detection and quantitation for ClO−, Cl−, ClO2−, ClO3−, and ClO4− ions; to evaluate the applicability of the developed method and its suitability for disinfectant analysis.Methods. Ionic chromatography using a conductometric detection system in isocratic elution mode.Results. The method developed for chromatographic determination of chlorine-containing ions can be used to quantify the content of hypochlorite, chloride, chlorite, chlorate, and perchlorate ions. In isocratic elution mode at 7.5 mM NaOH and a flow rate of 0.4 mL/min, the content of chlorine-containing ions can be determined with high sensitivity. The presented method does not require the use of expensive equipment for the ultrasensitive analysis of the studied compounds.Conclusions. A novel method for the simultaneous determination of hypochlorite, chloride, chlorite, chlorate, and perchlorate ions in case of their combined presence is proposed. The technique can be used to carry out routine control of the content of these disinfectant components during use, increasing their effectiveness at the same time as managing associated toxicological risks.
目标。建立溶液中次氯酸盐、氯化物、亚氯酸盐、氯酸盐和高氯酸盐离子的测定方法;确定ClO−、Cl−、ClO2−、ClO3−和ClO4−离子的检出限和定量限;评价该方法的适用性及其在消毒剂分析中的适用性。离子色谱用电导检测系统在等压洗脱模式下。所建立的含氯离子色谱测定方法可定量测定次氯酸盐、氯化物、亚氯酸盐、氯酸盐和高氯酸盐离子的含量。在7.5 mM NaOH和0.4 mL/min流速等容洗脱模式下,可以高灵敏度地测定含氯离子的含量。本方法不需要使用昂贵的仪器对所研究的化合物进行超灵敏分析。提出了一种同时测定次氯酸盐、氯化物、亚氯酸盐、氯酸盐和高氯酸盐离子的新方法。该技术可用于在使用过程中对这些消毒剂成分的含量进行常规控制,提高其有效性,同时管理相关的毒理学风险。