{"title":"A surface eddy current transducer for metal loss detection","authors":"Y. Reutov","doi":"10.17804/2410-9908.2022.6.016-024","DOIUrl":null,"url":null,"abstract":"The paper reports the results of an experimental study of the work of a surface eddy current transducer in terms of detecting and testing metal loss under one-sided access conditions. The transducer consists of an exciting coil and a microchip Hall-effect transducer placed in it. The phase shift of the voltage from the Hall probe output relative to the current in the exciting coil, measured by a digital phase meter, is used as an informative parameter. The experiments were carried out on a package of duralumin plates. It is shown that, when the thickness of the duralumin test object is 12.5 mm, a fairly linear transformation of metal loss from 0 to 50 % at a frequency of 640 Hz is possible. The results can be useful in the development of devices for detecting metal corrosion losses in non-ferromagnetic objects with a thickness of tens of millimeters under one-sided access conditions.","PeriodicalId":11165,"journal":{"name":"Diagnostics, Resource and Mechanics of materials and structures","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics, Resource and Mechanics of materials and structures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17804/2410-9908.2022.6.016-024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The paper reports the results of an experimental study of the work of a surface eddy current transducer in terms of detecting and testing metal loss under one-sided access conditions. The transducer consists of an exciting coil and a microchip Hall-effect transducer placed in it. The phase shift of the voltage from the Hall probe output relative to the current in the exciting coil, measured by a digital phase meter, is used as an informative parameter. The experiments were carried out on a package of duralumin plates. It is shown that, when the thickness of the duralumin test object is 12.5 mm, a fairly linear transformation of metal loss from 0 to 50 % at a frequency of 640 Hz is possible. The results can be useful in the development of devices for detecting metal corrosion losses in non-ferromagnetic objects with a thickness of tens of millimeters under one-sided access conditions.