{"title":"Polyvinyl chloride matrix membrane electrodes for manual and flow injection analysis of chloroquine in pharmaceutical preparations.","authors":"S. Hassan, M. Ahmed","doi":"10.1093/JAOAC/74.6.900","DOIUrl":null,"url":null,"abstract":"Two types of polyvinyl chloride (PVC) matrix membrane electrodes responsive to the antimalarial drug chloroquine have been constructed, electrochemically evaluated, compared and used in pharmaceutical analysis. Type 1 is the classic PVC model with chloroquine-tetraphenylborate (TPB) sensor; Type 2 is a coated silver disk without internal filling solution. Both electrode types exhibited rapid linear potentiometric response to the logarithmic concentration of diprotonated chloroquine cation in the 10(-1) - 10(-6)M range with calibration slopes 28-30 mV/concentration decade over the pH range 1.8-6.2. These electrodes were sensitive enough to permit determination of chloroquine phosphate at concentrations as low as 5 microgram/mL with good accuracy and precision. Determination of chloroquine in various pharmaceutical preparations using direct potentiometry and potentiometric titration with NaTPB gave an average recovery of 98.8% of the nominal values (SD 0.5%). The Type 2 electrode was also assessed in a flow-through sandwich cell for flow injection analysis. Results were compared with data obtained by the U.S. Pharmacopeia method.","PeriodicalId":14752,"journal":{"name":"Journal - Association of Official Analytical Chemists","volume":"26 1","pages":"900-5"},"PeriodicalIF":0.0000,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal - Association of Official Analytical Chemists","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/JAOAC/74.6.900","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Two types of polyvinyl chloride (PVC) matrix membrane electrodes responsive to the antimalarial drug chloroquine have been constructed, electrochemically evaluated, compared and used in pharmaceutical analysis. Type 1 is the classic PVC model with chloroquine-tetraphenylborate (TPB) sensor; Type 2 is a coated silver disk without internal filling solution. Both electrode types exhibited rapid linear potentiometric response to the logarithmic concentration of diprotonated chloroquine cation in the 10(-1) - 10(-6)M range with calibration slopes 28-30 mV/concentration decade over the pH range 1.8-6.2. These electrodes were sensitive enough to permit determination of chloroquine phosphate at concentrations as low as 5 microgram/mL with good accuracy and precision. Determination of chloroquine in various pharmaceutical preparations using direct potentiometry and potentiometric titration with NaTPB gave an average recovery of 98.8% of the nominal values (SD 0.5%). The Type 2 electrode was also assessed in a flow-through sandwich cell for flow injection analysis. Results were compared with data obtained by the U.S. Pharmacopeia method.