{"title":"Post-Correction of Under-Sampled Analog to Digital Converters","authors":"N. Björsell, P. Händel","doi":"10.1109/IMTC.2007.379429","DOIUrl":null,"url":null,"abstract":"Applications with wide bandwidth and high center frequencies force the analog to digital converter (ADC) to be active in a working range with less dynamic performance in relation to lower frequency bands. However using under-sampling techniques in combination with post-correction methods enable a combination of high sampling rate, wide bandwidth and low distortion. In this paper the employed dynamic post-correction is a combination of look-up tables and model based correction. The results are mainly based on measurements on a 12-bit 210 MSPS ADC. The improvement in total harmonic distortion and spurious free dynamic range are acceptable over a wide frequency range and it is robust to variations in amplitude.","PeriodicalId":93508,"journal":{"name":"... IEEE International Instrumentation and Measurement Technology Conference. IEEE International Instrumentation and Measurement Technology Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"... IEEE International Instrumentation and Measurement Technology Conference. IEEE International Instrumentation and Measurement Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2007.379429","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Applications with wide bandwidth and high center frequencies force the analog to digital converter (ADC) to be active in a working range with less dynamic performance in relation to lower frequency bands. However using under-sampling techniques in combination with post-correction methods enable a combination of high sampling rate, wide bandwidth and low distortion. In this paper the employed dynamic post-correction is a combination of look-up tables and model based correction. The results are mainly based on measurements on a 12-bit 210 MSPS ADC. The improvement in total harmonic distortion and spurious free dynamic range are acceptable over a wide frequency range and it is robust to variations in amplitude.