A robust procedure for P-wave detection and segmentation in high resolution 12-lead ECG

O. Escalona, L. Gavidia, G. Wright
{"title":"A robust procedure for P-wave detection and segmentation in high resolution 12-lead ECG","authors":"O. Escalona, L. Gavidia, G. Wright","doi":"10.1109/IEMBS.1996.647456","DOIUrl":null,"url":null,"abstract":"Reliable detection and measurement of the P-wave duration and position in high resolution 12-lead ECG recordings, was automated by means of a computer procedure which involved noise reduction by means of signal averaging, and bi-directional filtering of the P-wave at 25 Hz and the QRS complex at 40 Hz Then, algorithms for P-onset, P-offset and QRS-onset detection, allowed the estimation of P-wave duration and PQ interval, This computer procedure was clinically tested with 52 volunteers. The results indicated that, although reliable P-wave detection was possible in at least three leads in ally case, the measurement technique was most robust with leads I, II and V/sub 4/.","PeriodicalId":20427,"journal":{"name":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1996-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1996.647456","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Reliable detection and measurement of the P-wave duration and position in high resolution 12-lead ECG recordings, was automated by means of a computer procedure which involved noise reduction by means of signal averaging, and bi-directional filtering of the P-wave at 25 Hz and the QRS complex at 40 Hz Then, algorithms for P-onset, P-offset and QRS-onset detection, allowed the estimation of P-wave duration and PQ interval, This computer procedure was clinically tested with 52 volunteers. The results indicated that, although reliable P-wave detection was possible in at least three leads in ally case, the measurement technique was most robust with leads I, II and V/sub 4/.
高分辨率12导联心电图p波检测和分割的鲁棒程序
高分辨率12导联心电图记录中p波持续时间和位置的可靠检测和测量,通过计算机程序自动进行,该程序包括通过信号平均降噪、25 Hz p波和40 Hz QRS复合的双向滤波,然后,p波开始、p偏移和QRS开始检测算法,允许估计p波持续时间和PQ间隔,该计算机程序在52名志愿者中进行了临床测试。结果表明,虽然在大多数情况下,至少可以在三个引线上进行可靠的纵波检测,但使用引线I, II和V/sub 4/时测量技术最稳健。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信