Enkhjargal Bayarsaikhan, Sang-Wha Eom, U. Jung, Jae Hoon Lee
{"title":"Monolithic zirconia FPD on modified titanium bonding bases in limited interocclusal distance: A case report.","authors":"Enkhjargal Bayarsaikhan, Sang-Wha Eom, U. Jung, Jae Hoon Lee","doi":"10.1563/aaid-joi-D-19-00103","DOIUrl":null,"url":null,"abstract":"A 62-year-old male patient sought treatment for missing maxillary teeth. A diagnostic cast demonstrated that the interocclusal distance was insufficient. A five-unit screw-retained implant-supported fixed partial denture (FPD) was used to restore missing maxillary teeth. The restoration of multiple missing teeth using an implant-supported FPD is challenging when the interocclusal distance is limited due to lack of retention and inadequate esthetics. In this case, a hexagonal, screw-retained, and sublingually located titanium-based zirconia implant-supported FPD with a conical abutment base was used for restoration to overcome the limited interocclusal distance. This implant-supported FPD, consisting of CAD/CAM-designed monolithic zirconia cemented to a titanium bonding base in the laboratory, is expected to facilitate predictable retention and adequate esthetics as well as provide ease of retrieval.","PeriodicalId":77634,"journal":{"name":"The International journal of oral implantology : implantologist","volume":"37 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral implantology : implantologist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-19-00103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A 62-year-old male patient sought treatment for missing maxillary teeth. A diagnostic cast demonstrated that the interocclusal distance was insufficient. A five-unit screw-retained implant-supported fixed partial denture (FPD) was used to restore missing maxillary teeth. The restoration of multiple missing teeth using an implant-supported FPD is challenging when the interocclusal distance is limited due to lack of retention and inadequate esthetics. In this case, a hexagonal, screw-retained, and sublingually located titanium-based zirconia implant-supported FPD with a conical abutment base was used for restoration to overcome the limited interocclusal distance. This implant-supported FPD, consisting of CAD/CAM-designed monolithic zirconia cemented to a titanium bonding base in the laboratory, is expected to facilitate predictable retention and adequate esthetics as well as provide ease of retrieval.