{"title":"Effect of Increasing Sea Water Temperature on Performance of Steam Turbine of Muara Tawar Power Plant","authors":"Nastopo Darmawan, T. Yuwono","doi":"10.12962/j20882033.v30i2.4994","DOIUrl":null,"url":null,"abstract":"Muara Tawar Power Plant is located on the coast of Bekasi, West Java, Indonesia. Along with the economic development, there are plans to do reclamation the sea around Muara Tawar Power Plant and build around it as a port and industrial estate. This could potentially lead to an increase in sea water temperatures. This paper aims to determine the effect of increasing sea water temperature on the performance of steam turbine 1.4 in Muara Tawar Power Plant, which uses sea water as a condenser cooling medium. The intended performance is the output power of the steam turbine, the condenser pressure and the system efficiency. Steam turbine 1.4 has 225 MW installed output power, supplied from 3 HRSG (Heat Recovery Steam Generator).Analysis of the effect of sea water temperature rise on steam turbine performance is carried out by using the cycle-tempo software. The main equipment of steam turbine is modeled in cycle-tempo, then model is validated by comparing with design data. Varies sea water temperature then is inputted on model in order to obtain the output power of steam turbine, condenser pressure and system efficiency. The results show that for every 1˚C increase in condenser cooling water temperature extracted from seawater near the plant, the output power of the plant decreased by about 0.171%, the condenser pressure increased by about 5.146%, and the system efficiency decreased by about 0.168%.","PeriodicalId":14549,"journal":{"name":"IPTEK: The Journal for Technology and Science","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IPTEK: The Journal for Technology and Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12962/j20882033.v30i2.4994","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
Muara Tawar Power Plant is located on the coast of Bekasi, West Java, Indonesia. Along with the economic development, there are plans to do reclamation the sea around Muara Tawar Power Plant and build around it as a port and industrial estate. This could potentially lead to an increase in sea water temperatures. This paper aims to determine the effect of increasing sea water temperature on the performance of steam turbine 1.4 in Muara Tawar Power Plant, which uses sea water as a condenser cooling medium. The intended performance is the output power of the steam turbine, the condenser pressure and the system efficiency. Steam turbine 1.4 has 225 MW installed output power, supplied from 3 HRSG (Heat Recovery Steam Generator).Analysis of the effect of sea water temperature rise on steam turbine performance is carried out by using the cycle-tempo software. The main equipment of steam turbine is modeled in cycle-tempo, then model is validated by comparing with design data. Varies sea water temperature then is inputted on model in order to obtain the output power of steam turbine, condenser pressure and system efficiency. The results show that for every 1˚C increase in condenser cooling water temperature extracted from seawater near the plant, the output power of the plant decreased by about 0.171%, the condenser pressure increased by about 5.146%, and the system efficiency decreased by about 0.168%.
Muara Tawar发电厂位于印度尼西亚西爪哇勿加西海岸。随着经济的发展,有计划在Muara Tawar发电厂周围进行填海,并在其周围建造港口和工业区。这可能会导致海水温度升高。本文旨在确定提高海水温度对Muara Tawar电厂以海水作为冷凝器冷却介质的1.4汽轮机性能的影响。预期的性能是汽轮机的输出功率、冷凝器压力和系统效率。汽轮机1.4具有225兆瓦的安装输出功率,由3个HRSG(热回收蒸汽发生器)提供。利用循环速度软件分析了海水温度升高对汽轮机性能的影响。对汽轮机主要设备进行了循环速度建模,并与设计数据进行了对比验证。然后在模型中输入变化的海水温度,得到汽轮机的输出功率、冷凝器压力和系统效率。结果表明,从电厂附近海水中提取的冷凝器冷却水温度每升高1℃,电厂输出功率降低约0.171%,冷凝器压力升高约5.146%,系统效率降低约0.168%。