{"title":"Radiation dose evaluation to male adult reference phantom from using three types of cloths with naturally occurring radioactive material","authors":"Yan Kong, Hui Zhang, Bo Yang","doi":"10.3760/CMA.J.ISSN.0254-5098.2020.01.008","DOIUrl":null,"url":null,"abstract":"Objective \nTo evaluate annual skin equivalent dose and annual effective dose to consumers arising from three types of cloths samples containing naturally occurring radioactive material (NORM). \n \n \nMethods \nFirstly, measurement of radioactivity in three types of cloths were made with γ-ray spectrometer. And then, theoretical exposure scenarios were simulated with Monte Carlo software to calculate organ dose and effective dose by using ICRP reference voxel male phantom. Finally, annual skin equivalent dose and effective dose to consumers from these cloths samples were evaluated. \n \n \nResults \nIn the wrapped and covered estimation models used in this study, sample mass ranged from 135 to 7 197 g, annual skin equivalent dose to consumers from these cloths samples from 155.41 to 9 028.61 μSv, and annual effective dose from 11.91 to 1 234.44 μSv. \n \n \nConclusions \nNORM-added consumer products would cause some radiation hazard to human body. \n \n \nKey words: \nNORM; Consumer products; Dose evaluation","PeriodicalId":36403,"journal":{"name":"中华放射医学与防护杂志","volume":"22 1","pages":"47-50"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华放射医学与防护杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.0254-5098.2020.01.008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
To evaluate annual skin equivalent dose and annual effective dose to consumers arising from three types of cloths samples containing naturally occurring radioactive material (NORM).
Methods
Firstly, measurement of radioactivity in three types of cloths were made with γ-ray spectrometer. And then, theoretical exposure scenarios were simulated with Monte Carlo software to calculate organ dose and effective dose by using ICRP reference voxel male phantom. Finally, annual skin equivalent dose and effective dose to consumers from these cloths samples were evaluated.
Results
In the wrapped and covered estimation models used in this study, sample mass ranged from 135 to 7 197 g, annual skin equivalent dose to consumers from these cloths samples from 155.41 to 9 028.61 μSv, and annual effective dose from 11.91 to 1 234.44 μSv.
Conclusions
NORM-added consumer products would cause some radiation hazard to human body.
Key words:
NORM; Consumer products; Dose evaluation