Characterization of CMOS-MEMS device for acetone vapor detection in exhaled breath

A. Rabih, M. H. M. Md Khir, A. Y. Ahmed, M. A. A. Ahmed, J. Dennis
{"title":"Characterization of CMOS-MEMS device for acetone vapor detection in exhaled breath","authors":"A. Rabih, M. H. M. Md Khir, A. Y. Ahmed, M. A. A. Ahmed, J. Dennis","doi":"10.1109/RSM.2015.7354966","DOIUrl":null,"url":null,"abstract":"A MEMS vapor sensor for acetone detection in exhaled breath (EB) has been fabricated using 0.35 μm CMOS technology. Acetone vapor in EB is used as a non-invasive method for diabetes screening, which is currently conducted invasively by measuring blood glucose in blood. This paper studies the characterization of polysilicon piezoresistors, heater and temperature sensor embedded in the device. The measured resistances were found to be close to the modelled values within 1.1-6.8% error. Temperature coefficient of resistance (TCR) of the temperature sensor in a range of 25-100°C was found. TCR increases linearly with increasing the temperature and decreases linearly with decreasing the temperature. It was found to be 0.0033/°C for the increasing temperature and 0.0034/°C for the decreasing temperature, compared to 0.0038/°C reported in the literature, with an error of 13% and 10.5%, respectively.","PeriodicalId":6667,"journal":{"name":"2015 IEEE Regional Symposium on Micro and Nanoelectronics (RSM)","volume":"21 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Regional Symposium on Micro and Nanoelectronics (RSM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RSM.2015.7354966","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A MEMS vapor sensor for acetone detection in exhaled breath (EB) has been fabricated using 0.35 μm CMOS technology. Acetone vapor in EB is used as a non-invasive method for diabetes screening, which is currently conducted invasively by measuring blood glucose in blood. This paper studies the characterization of polysilicon piezoresistors, heater and temperature sensor embedded in the device. The measured resistances were found to be close to the modelled values within 1.1-6.8% error. Temperature coefficient of resistance (TCR) of the temperature sensor in a range of 25-100°C was found. TCR increases linearly with increasing the temperature and decreases linearly with decreasing the temperature. It was found to be 0.0033/°C for the increasing temperature and 0.0034/°C for the decreasing temperature, compared to 0.0038/°C reported in the literature, with an error of 13% and 10.5%, respectively.
呼气丙酮蒸汽检测用CMOS-MEMS器件的特性研究
采用0.35 μm CMOS工艺制备了用于呼气丙酮检测的MEMS蒸汽传感器。EB中的丙酮蒸气被用作糖尿病筛查的非侵入性方法,目前是通过测量血液中的血糖进行侵入性筛查。本文研究了器件内嵌的多晶硅压敏电阻、加热器和温度传感器的特性。测量电阻与模型值接近,误差在1.1 ~ 6.8%之间。温度传感器的电阻温度系数(TCR)在25 ~ 100℃范围内。TCR随温度的升高而线性增加,随温度的降低而线性降低。与文献报道的0.0038/°C相比,温度升高时的误差为0.0033/°C,温度降低时的误差为0.0034/°C,误差分别为13%和10.5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信