Conducted emission simulation and measurement of interleaved DC-DC converters

Pub Date : 2022-01-01 DOI:10.36244/icj.2022.2.4
T. Kőnig, L. Nagy
{"title":"Conducted emission simulation and measurement of interleaved DC-DC converters","authors":"T. Kőnig, L. Nagy","doi":"10.36244/icj.2022.2.4","DOIUrl":null,"url":null,"abstract":"Switching-Mode Power Supplies (SMPS) are often used to power on-board satellite payloads due to their good conversion efficiency. However, they emit radiated and conducted noise, which can disturb the operation of other payloads. The current ripple sum of the power supplies will appear on the power bus. There are many methods to reduce this summarized noise, one of them is to interleave the on-switching times of the converters. This ripple cancellation method can decrease the noise component on the switching frequency and on its upper harmonics. In this article we are going to demonstrate the effects of the distributed interleaving with a measurement platform consisting of two Pulse Width Modulation (PWM) controlled Buck controllers.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36244/icj.2022.2.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Switching-Mode Power Supplies (SMPS) are often used to power on-board satellite payloads due to their good conversion efficiency. However, they emit radiated and conducted noise, which can disturb the operation of other payloads. The current ripple sum of the power supplies will appear on the power bus. There are many methods to reduce this summarized noise, one of them is to interleave the on-switching times of the converters. This ripple cancellation method can decrease the noise component on the switching frequency and on its upper harmonics. In this article we are going to demonstrate the effects of the distributed interleaving with a measurement platform consisting of two Pulse Width Modulation (PWM) controlled Buck controllers.
分享
查看原文
对交错DC-DC变换器进行了发射仿真和测量
开关模式电源(SMPS)由于其良好的转换效率,经常被用于为星载卫星有效载荷供电。然而,它们会发出辐射和传导噪声,这可能会干扰其他有效载荷的运行。电源的当前纹波和将出现在电源总线上。有许多方法可以降低这种汇总噪声,其中一种方法是将变换器的导通次数穿插在一起。这种纹波抵消方法可以降低开关频率及其上谐波上的噪声分量。在本文中,我们将用一个由两个脉宽调制(PWM)控制的Buck控制器组成的测量平台来演示分布式交错的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信