Characterization and Removal Efficiency of Central Effluent Treatment Plant (CETP)

U. Monira, G. Sattar, M. Mostafa
{"title":"Characterization and Removal Efficiency of Central Effluent Treatment Plant (CETP)","authors":"U. Monira, G. Sattar, M. Mostafa","doi":"10.3126/josem.v2i1.53116","DOIUrl":null,"url":null,"abstract":"Tannery industries are one of the most pollution-generating industries in the world. Tannery wastewater is usually characterized by high BOD, COD, TDS, and TSS and a high percentage of dissolved organic and inorganic matter. The central effluent treatment plant (CETP) of industry plays a vital role in sustainable industrial waste management and saves different lives from harmful effects. The study aimed to analyze various physicochemical parameters of the composite tannery influent and effluent as well as the removal efficiency of the CETP of the Savar Tannery Industrial Zone in Bangladesh. It was carried out at Savar Upazila, situated in the northwest part of Dhaka, Bangladesh. The samples were collected three times (pre-monsoon, monsoon, and post-monsoon) in a year, from monsoon 2021 to pre-monsoon 2022. The major water quality parameters for the influents and effluents included pH, BOD, COD, TDS, TSS, NO3-, SO42-, HCO3-, PO43-, Cl-, Na, Ca, Cr, Fe, Cu, Zn, and Pb. Most of the parameters, especially BOD, COD, TDS, and TSS after treatment, exceeded the standard permissible limits of effluent discharge prescribed by the ISW-BDS-ECR (1997), DoE-BD, and NEQS (2000), and these values were two times higher than the permissible limit. The DO value was four times lower than the permissible limit, indicating heavily polluted water. The concentration of the cations in the tannery effluents was in the following order: Na>Ca>Cr>Fe>Cu>Zn>Pb. The analysis results illustrated that the overall removal efficiency of the CETP was about 47%. The study observed that the performance of the CETP was not satisfactory, and hence it needs further improvement in the treating capacity for sustainable industrial wastewater management.","PeriodicalId":32450,"journal":{"name":"IJEMS Indonesian Journal of Environmental Management and Sustainability","volume":"43 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJEMS Indonesian Journal of Environmental Management and Sustainability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/josem.v2i1.53116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Tannery industries are one of the most pollution-generating industries in the world. Tannery wastewater is usually characterized by high BOD, COD, TDS, and TSS and a high percentage of dissolved organic and inorganic matter. The central effluent treatment plant (CETP) of industry plays a vital role in sustainable industrial waste management and saves different lives from harmful effects. The study aimed to analyze various physicochemical parameters of the composite tannery influent and effluent as well as the removal efficiency of the CETP of the Savar Tannery Industrial Zone in Bangladesh. It was carried out at Savar Upazila, situated in the northwest part of Dhaka, Bangladesh. The samples were collected three times (pre-monsoon, monsoon, and post-monsoon) in a year, from monsoon 2021 to pre-monsoon 2022. The major water quality parameters for the influents and effluents included pH, BOD, COD, TDS, TSS, NO3-, SO42-, HCO3-, PO43-, Cl-, Na, Ca, Cr, Fe, Cu, Zn, and Pb. Most of the parameters, especially BOD, COD, TDS, and TSS after treatment, exceeded the standard permissible limits of effluent discharge prescribed by the ISW-BDS-ECR (1997), DoE-BD, and NEQS (2000), and these values were two times higher than the permissible limit. The DO value was four times lower than the permissible limit, indicating heavily polluted water. The concentration of the cations in the tannery effluents was in the following order: Na>Ca>Cr>Fe>Cu>Zn>Pb. The analysis results illustrated that the overall removal efficiency of the CETP was about 47%. The study observed that the performance of the CETP was not satisfactory, and hence it needs further improvement in the treating capacity for sustainable industrial wastewater management.
中央污水处理厂(CETP)的特性及去除率
制革业是世界上污染最严重的行业之一。制革废水通常具有高BOD、COD、TDS和TSS以及高溶解有机物和无机物百分比的特点。工业中央污水处理厂(CETP)在可持续的工业废物管理中起着至关重要的作用,可以使不同的生命免受有害影响。该研究旨在分析孟加拉国Savar制革厂工业区复合制革厂进出水的各种物理化学参数以及CETP的去除效率。调查是在孟加拉国达卡西北部的Savar Upazila进行的。从2021年季风到2022年季风前,在一年内收集了三次样本(季风前,季风和季风后)。进水和出水的主要水质参数包括pH、BOD、COD、TDS、TSS、NO3-、SO42-、HCO3-、PO43-、Cl-、Na、Ca、Cr、Fe、Cu、Zn和Pb。大部分参数,特别是处理后的BOD、COD、TDS和TSS均超过了ISW-BDS-ECR(1997)、DoE-BD和NEQS(2000)规定的污水排放标准允许限值,超过允许限值2倍以上。DO值低于允许值的4倍,表明水质严重污染。制革废水中阳离子的浓度顺序为:Na>Ca>Cr>Fe>Cu>Zn>Pb。分析结果表明,CETP的总去除率约为47%。研究发现,CETP的性能并不令人满意,因此需要进一步提高处理能力,以实现工业废水的可持续管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
17
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书