Order Reduction of Continuous Interval Zeta Converter Model using Direct Truncation Method

V. Meena, Rishika Agrawal, Rajat Gumber, Anuja R. Tipare, Vinay Singh
{"title":"Order Reduction of Continuous Interval Zeta Converter Model using Direct Truncation Method","authors":"V. Meena, Rishika Agrawal, Rajat Gumber, Anuja R. Tipare, Vinay Singh","doi":"10.1109/AISP53593.2022.9760520","DOIUrl":null,"url":null,"abstract":"Zeta Converter consists of two inductors and two capacitors, hence it is a fourth order system. Output voltage of a zeta converter can be lower or higher as compared to the input voltage. In this paper, small signal dynamic model is obtained using steady state averaging technique and further direct truncation method is used to reduce the order of the given fourth order test case to first, second and third order systems respectively. Impulse response and step response are plotted as well as integral square error is calculated for lower and upper limit of reduced order transfer functions. The results presented prove the applicability and effectiveness of the proposed method.","PeriodicalId":6793,"journal":{"name":"2022 2nd International Conference on Artificial Intelligence and Signal Processing (AISP)","volume":"29 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 2nd International Conference on Artificial Intelligence and Signal Processing (AISP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AISP53593.2022.9760520","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Zeta Converter consists of two inductors and two capacitors, hence it is a fourth order system. Output voltage of a zeta converter can be lower or higher as compared to the input voltage. In this paper, small signal dynamic model is obtained using steady state averaging technique and further direct truncation method is used to reduce the order of the given fourth order test case to first, second and third order systems respectively. Impulse response and step response are plotted as well as integral square error is calculated for lower and upper limit of reduced order transfer functions. The results presented prove the applicability and effectiveness of the proposed method.
用直接截断法降阶连续区间Zeta转换器模型
Zeta变换器由两个电感和两个电容器组成,因此它是一个四阶系统。与输入电压相比,zeta转换器的输出电压可以低或高。本文采用稳态平均技术得到小信号动态模型,并进一步采用直接截断法将给定的四阶测试用例分别降阶为一阶、二阶和三阶系统。绘制了脉冲响应和阶跃响应,并计算了降阶传递函数下限和上限的积分平方误差。实验结果证明了该方法的适用性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信