New correlation for liquid hold-up of sodium citrate buffer solution in a Raschig ring packed column

I. Bágyi , E. Márki , E. Békássy-Molnár
{"title":"New correlation for liquid hold-up of sodium citrate buffer solution in a Raschig ring packed column","authors":"I. Bágyi ,&nbsp;E. Márki ,&nbsp;E. Békássy-Molnár","doi":"10.1016/S0950-4214(96)00016-3","DOIUrl":null,"url":null,"abstract":"<div><p>Dynamic liquid hold-up was measured with an air/aqueous sodium citrate buffer solution at 20–40 °C, and an air/water system at 23 °C, in a 0.1 m diameter/1 m high glass column covered by a heat-isolating vacuum jacket and packed with 0.012 m nominal size ceramic Raschig rings. The superficial gas velocity range was extended to 1.2 m s<sup>−1</sup>. Experimental results of this work were compared with literature data, with different correlations and with a general equation. All expressions were found to be unacceptable for the air/buffer system and useable for the air/water system. In the case of the air/buffer solution a new correlation is recommended on the basis of our measured data and literature values.</p></div>","PeriodicalId":12586,"journal":{"name":"Gas Separation & Purification","volume":"10 4","pages":"Pages 199-205"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0950-4214(96)00016-3","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gas Separation & Purification","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0950421496000163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Dynamic liquid hold-up was measured with an air/aqueous sodium citrate buffer solution at 20–40 °C, and an air/water system at 23 °C, in a 0.1 m diameter/1 m high glass column covered by a heat-isolating vacuum jacket and packed with 0.012 m nominal size ceramic Raschig rings. The superficial gas velocity range was extended to 1.2 m s−1. Experimental results of this work were compared with literature data, with different correlations and with a general equation. All expressions were found to be unacceptable for the air/buffer system and useable for the air/water system. In the case of the air/buffer solution a new correlation is recommended on the basis of our measured data and literature values.

拉希环填充塔中柠檬酸钠缓冲溶液液持率的新关联
在空气/柠檬酸钠水溶液(20-40℃)和空气/水系统(23℃)中,在直径0.1 m /1 m高的玻璃柱中测量动态液持率,玻璃柱上覆盖隔热真空套,并填充0.012 m标称尺寸的陶瓷拉希环。表面气速范围扩大到1.2 m s−1。本工作的实验结果与文献数据进行了比较,具有不同的相关性和一般方程。所有的表达式对于空气/缓冲系统是不可接受的,对于空气/水系统是可用的。在空气/缓冲溶液的情况下,根据我们的测量数据和文献值,建议采用新的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信