Radiological equipment and accessories as sources of nosocomial infection

Salma Suleiman Dauda, M. Sidi, Aziza Oretokun, H. Mohammed, A. Dare
{"title":"Radiological equipment and accessories as sources of nosocomial infection","authors":"Salma Suleiman Dauda, M. Sidi, Aziza Oretokun, H. Mohammed, A. Dare","doi":"10.48153/jrrs/2016/qxdu7647","DOIUrl":null,"url":null,"abstract":"Background: Nosocomial infections have become a major challenge in health institutions, as they affect the quality of health care delivered. The radiology department is one of the mainstays of modern medicine. It is therefore, necessary to assess its contamination by nosocomial organisms.Aim: The study aims at identifying the nosocomial bacteria associated with imaging equipment and accessories in Aminu Kano Teaching Hospital, Kano, Nigeria.Methods: The study design was prospective and cross-sectional in nature, and was conducted between Oct 2014 to Jan 2015 using disproportionate stratified random sampling method. Four different conventional x-ray units, fluoroscopy, computed tomography, angiography and ultrasound units were selected. Swabs were collected from the surfaces of the selected parts of the equipment and accessories after working hours in each unit. The swabs were taken to the microbiology laboratory for culturing and identification using standard laboratory procedure. A total of 200 cultured samples were used in the study. The collected data was analyzed using SPSS version 16.0 software.Results: Bacteria were isolated in 43.5 % (n = 87) of all the swab samples with ultrasound transducer as major culture. Specific bacteria isolated were: Staphylococcus aureus (n = 65; 74.7 %), Pseudomonas aeruginosa (n = 14; 16.1 %), Bacillus spp (n = 6; 6.9 %), Klebsiella spp (n = 1; 1.1 %) and Proteus spp (n = 1; 1.1 %). Methylated spirit was the most effective chemical disinfectant. Conclusion: Radiology equipment and accessories in Aminu Kano Teaching Hospital are not entirely free of bacteria. Meticulous attention to disinfection will safeguard staff and other patients from nosocomial infections.","PeriodicalId":16919,"journal":{"name":"Journal of Radiography and Radiation Sciences","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiography and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.48153/jrrs/2016/qxdu7647","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Nosocomial infections have become a major challenge in health institutions, as they affect the quality of health care delivered. The radiology department is one of the mainstays of modern medicine. It is therefore, necessary to assess its contamination by nosocomial organisms.Aim: The study aims at identifying the nosocomial bacteria associated with imaging equipment and accessories in Aminu Kano Teaching Hospital, Kano, Nigeria.Methods: The study design was prospective and cross-sectional in nature, and was conducted between Oct 2014 to Jan 2015 using disproportionate stratified random sampling method. Four different conventional x-ray units, fluoroscopy, computed tomography, angiography and ultrasound units were selected. Swabs were collected from the surfaces of the selected parts of the equipment and accessories after working hours in each unit. The swabs were taken to the microbiology laboratory for culturing and identification using standard laboratory procedure. A total of 200 cultured samples were used in the study. The collected data was analyzed using SPSS version 16.0 software.Results: Bacteria were isolated in 43.5 % (n = 87) of all the swab samples with ultrasound transducer as major culture. Specific bacteria isolated were: Staphylococcus aureus (n = 65; 74.7 %), Pseudomonas aeruginosa (n = 14; 16.1 %), Bacillus spp (n = 6; 6.9 %), Klebsiella spp (n = 1; 1.1 %) and Proteus spp (n = 1; 1.1 %). Methylated spirit was the most effective chemical disinfectant. Conclusion: Radiology equipment and accessories in Aminu Kano Teaching Hospital are not entirely free of bacteria. Meticulous attention to disinfection will safeguard staff and other patients from nosocomial infections.
作为医院感染源的放射设备和附件
背景:医院感染已成为卫生机构面临的主要挑战,因为它们影响到所提供的卫生保健质量。放射科是现代医学的支柱之一。因此,有必要评估其受医院微生物的污染情况。目的:本研究旨在鉴定尼日利亚卡诺Aminu Kano教学医院与成像设备及附件相关的院内细菌。方法:采用前瞻性和横断面设计,研究时间为2014年10月至2015年1月,采用不成比例分层随机抽样方法。选择四个不同的常规x线单元、透视、计算机断层扫描、血管造影和超声单元。在每个单元的工作时间后,从设备和附件的选定部件的表面收集拭子。拭子被带到微生物实验室进行培养和鉴定,使用标准的实验室程序。本研究共使用200个培养样本。采用SPSS 16.0版软件对收集的数据进行分析。结果:以超声换能器为主要培养物的拭子样本中,细菌分离率为43.5% (n = 87)。分离到的特异性细菌有:金黄色葡萄球菌(n = 65;74.7%),铜绿假单胞菌(n = 14;16.1%),芽孢杆菌(n = 6;6.9%),克雷伯氏菌(n = 1;1.1%)和变形杆菌(n = 1;1.1%)。甲基化酒精是最有效的化学消毒剂。结论:明野教学医院放射设备及附属设备并非完全没有细菌。对消毒的细致关注将保护工作人员和其他患者免受院内感染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信