{"title":"Hybrid State Estimation for Diverse Combination of PMU Measurements","authors":"P. Ghosh, A. Tahabilder, Soumesh Chatterjee, Milon Kumer","doi":"10.1109/ICISET.2018.8745610","DOIUrl":null,"url":null,"abstract":"Continuous estimation of system states is mandatory for proper operation, control and protection of power system. This paper presents an observation of state estimation improvements for IEEE 14 bus system incorporating the Phasor Measurement Unit (PMU) measurements with traditional SCADA measurements. Initially, the optimal number of PMU requirement for complete observability of this test case is identified using the Integer Linear Programming (ILP) optimization technique. Then, the diverse combinations of the PMU requirement are checked. Incorporation of PMU measurements with traditional measurements for finally selected 4 cases are done. Eventually, the improvement of state estimation is observed for those cases by a graphical representation.","PeriodicalId":6608,"journal":{"name":"2018 International Conference on Innovations in Science, Engineering and Technology (ICISET)","volume":"31 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Innovations in Science, Engineering and Technology (ICISET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISET.2018.8745610","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Continuous estimation of system states is mandatory for proper operation, control and protection of power system. This paper presents an observation of state estimation improvements for IEEE 14 bus system incorporating the Phasor Measurement Unit (PMU) measurements with traditional SCADA measurements. Initially, the optimal number of PMU requirement for complete observability of this test case is identified using the Integer Linear Programming (ILP) optimization technique. Then, the diverse combinations of the PMU requirement are checked. Incorporation of PMU measurements with traditional measurements for finally selected 4 cases are done. Eventually, the improvement of state estimation is observed for those cases by a graphical representation.
不同PMU测量组合的混合状态估计
系统状态的连续估计是电力系统正常运行、控制和保护的必要条件。本文介绍了将相量测量单元(PMU)测量与传统的SCADA测量相结合的IEEE 14总线系统状态估计改进的观察。首先,使用整数线性规划(ILP)优化技术确定了该测试用例完全可观察性的PMU需求的最优数量。然后,检查了PMU需求的不同组合。最后选取了4种情况,将PMU测量与传统测量相结合。最后,通过图形化表示,观察到这些情况下状态估计的改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信