{"title":"The temperature dependence of space charge accumulation in cross-linked polyethylene","authors":"K. Bambery, R. Fleming","doi":"10.1109/ISE.1996.578031","DOIUrl":null,"url":null,"abstract":"This paper presents the results of laser-induced-pressure-pulse (LIPP) measurements of space charge accumulation in 0.5 mm thick planar XLPE samples with aluminium electrodes, over the temperature range 30–90°C. The applied field strength was 10 kV mm−1. The increase in transit time of the pressure pulse across the sample with increasing temperature indicated that Young's modulus decreased by 50% from 30 to 90°C. It was concluded that electrons injected at the cathode are transported to the anode at temperatures above 40°C, and that electron traps cause an accumulation of negative charge immediately adjacent to both cathode and anode. It appears that a concentration of impurity molecules accumulates close to the cathode, and field-assisted thermal ionisation of these molecules generates an immobile positive space charge adjoining the electronic space charge adjacent to the cathode.","PeriodicalId":17333,"journal":{"name":"Journal of thermal analysis","volume":"21 1","pages":"19-31"},"PeriodicalIF":0.0000,"publicationDate":"1996-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of thermal analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISE.1996.578031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24
Abstract
This paper presents the results of laser-induced-pressure-pulse (LIPP) measurements of space charge accumulation in 0.5 mm thick planar XLPE samples with aluminium electrodes, over the temperature range 30–90°C. The applied field strength was 10 kV mm−1. The increase in transit time of the pressure pulse across the sample with increasing temperature indicated that Young's modulus decreased by 50% from 30 to 90°C. It was concluded that electrons injected at the cathode are transported to the anode at temperatures above 40°C, and that electron traps cause an accumulation of negative charge immediately adjacent to both cathode and anode. It appears that a concentration of impurity molecules accumulates close to the cathode, and field-assisted thermal ionisation of these molecules generates an immobile positive space charge adjoining the electronic space charge adjacent to the cathode.