{"title":"Validation of a Robust and High-Throughput HPLC-MS/MS Method to Determine Amantadine Levels in Human Plasma","authors":"K. Wank","doi":"10.17145/JAB.18.008","DOIUrl":null,"url":null,"abstract":"RESULTS: Lower limit of quantitation was validated to be 15 ng/mL with a reduced sample volume of 20 μL comparing with previously reported methods. Calibration curve was linear over a concentration range of 15-2000 ng/mL. In addition to linearity, other parameters including matrix selectivity, matrix effect, recovery, method accuracy and precision, sensitivity, and stabilities of amantadine under storage conditions were also fully validated following the guidance of United States Food and Drug Administration.","PeriodicalId":15014,"journal":{"name":"Journal of Applied Bioanalysis","volume":"29 1","pages":"51-61"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Bioanalysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17145/JAB.18.008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

RESULTS: Lower limit of quantitation was validated to be 15 ng/mL with a reduced sample volume of 20 μL comparing with previously reported methods. Calibration curve was linear over a concentration range of 15-2000 ng/mL. In addition to linearity, other parameters including matrix selectivity, matrix effect, recovery, method accuracy and precision, sensitivity, and stabilities of amantadine under storage conditions were also fully validated following the guidance of United States Food and Drug Administration.
验证用于测定人体血浆中金刚烷胺水平的可靠高通量 HPLC-MS/MS 方法
结果:与以往报道的方法相比,定量下限为15 ng/mL,样品体积减少了20 μL。在15 ~ 2000 ng/mL浓度范围内,校正曲线呈线性。除线性外,基质选择性、基质效应、回收率、方法准确度和精密度、灵敏度、金刚烷胺在贮存条件下的稳定性等参数也按照美国食品和药物管理局的指导进行了充分验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信